Journal: :Journal of bacteriology 2013
Zegbeh Z Kpadeh Max Jameson-Lee Anthony J Yeh Olga Chertihin Igor A Shumilin Rafik Dey Shandra R Day Paul S Hoffman

The extracytoplasmic assembly of the Dot/Icm type IVb secretion system (T4SS) of Legionella pneumophila is dependent on correct disulfide bond (DSB) formation catalyzed by a novel and essential disulfide bond oxidoreductase DsbA2 and not by DsbA1, a second nonessential DSB oxidoreductase. DsbA2, which is widely distributed in the microbial world, is phylogenetically distinct from the canonical ...

Journal: :Building Simulation Conference proceedings 2021

During the COVID-19 lockdown prolonged closure of sport facilities is causing Legionella growth in system. Based on an in-house developed simulation tool, L. pneumophila concentration predicted dynamically throughout system and restart guidelines are evaluated.

Journal: :Journal of clinical pathology 1987
R J Fallon R E Johnston

The antibody response of patients infected with Legionella pneumophila serogroup 1 in a common source outbreak was investigated. Heat-killed antigens from L pneumophila serogroups 1-3 and 6-10, plus several other strains of L pneumophila, together with 13 other species of legionellas were used in an indirect fluorescence antibody test. Formolised yolk sac antigens made from L pneumophila serogr...

2013
Lisa Conza Simona Casati Pagani Valeria Gaia

Several species of Legionella cause Legionnaires' disease (LD). Infection may occur through inhalation of Legionella or amoebal vesicles. The reservoirs of Legionella are water, soil, potting soil and compost. Some species of free-living amoebae (FLA) that are naturally present in water and soil were described as hosts for Legionella. This study aimed to understand whether or not the composting...

Journal: :Journal of toxicology and environmental health. Part A 2007
Yusen E Lin Wen-ming Lu Hsin-I Huang Wen-kuei Huang

Acquisition of sporadic community-acquired legionnaires' disease has been linked to hot springs and whirlpool baths. Outbreaks of hot spring-associated legionnaires' disease were reported in Japan in the last few years. Although the mode of transmission is unclear, the presence of Legionella in hot springs may discourage hot springs resort visits by the general public. An environmental survey w...

Journal: :Infection control and hospital epidemiology 2007
Janet E Stout Robert R Muder Sue Mietzner Marilyn M Wagener Mary Beth Perri Kathleen DeRoos Dona Goodrich William Arnold Theresa Williamson Ola Ruark Christine Treadway Elizabeth C Eckstein Debra Marshall Mary Ellen Rafferty Kathleen Sarro Joann Page Robert Jenkins Gina Oda Kathleen J Shimoda Marcus J Zervos Marvin Bittner Sharon L Camhi Anand P Panwalker Curtis J Donskey Minh-Hong Nguyen Mark Holodniy Victor L Yu

OBJECTIVE Hospital-acquired Legionella pneumonia has a fatality rate of 28%, and the source is the water distribution system. Two prevention strategies have been advocated. One approach to prevention is clinical surveillance for disease without routine environmental monitoring. Another approach recommends environmental monitoring even in the absence of known cases of Legionella pneumonia. We de...

Journal: :Infection and immunity 2006
Hayley J Newton Fiona M Sansom Vicki Bennett-Wood Elizabeth L Hartland

Legionella pneumophila is a ubiquitous environmental organism and a facultative intracellular pathogen of humans. To identify genes that may contribute to the virulence of L. pneumophila, we performed genomic subtractive hybridization between L. pneumophila serogroup 1 strain 02/41 and L. micdadei strain 02/42. A total of 144 L. pneumophila-specific clones were sequenced, revealing 151 genes th...

2010
Jaana Kusnetsov Liisa-Kaarina Neuvonen Timo Korpio Søren A Uldum Silja Mentula Tuula Putus Nhu Nguyen Tran Minh Kari-Pekka Martimo

BACKGROUND Finnish and Swedish waste water systems used by the forest industry were found to be exceptionally heavily contaminated with legionellae in 2005. CASE PRESENTATION We report two cases of severe pneumonia in employees working at two separate mills in Finland in 2006. Legionella serological and urinary antigen tests were used to diagnose Legionnaires' disease in the symptomatic emplo...

Journal: :Journal of clinical microbiology 2013
Alvaro J Benitez Jonas M Winchell

We developed a single-tube multiplex real-time PCR assay capable of simultaneously detecting and discriminating Legionella spp., Legionella pneumophila, and Legionella pneumophila serogroup 1 in primary specimens. Evaluation of 21 clinical specimens and 115 clinical isolates demonstrated this assay to be a rapid, high-throughput diagnostic test with 100% specificity that may aid during legionel...

Journal: :Emerging Infectious Diseases 2008
Axel Mauroy Hugues Guyot Kris De Clercq Dominique Cassart Etienne Thiry Claude Saegerman

5. Gaia V, Fry NK, Afshar B, Luck PC, Meugnier H, Etienne J, et al. Consensus sequence-based scheme for epidemiological typing of clinical and environmental isolates of Legionella pneumophila. J Clin Microbiol. 2005;43:2047–52. 6. Ratzow S, Gaia V, Helbig JH, Fry NK, Luck PC. Addition of neuA, the gene encoding N-acylneuraminate cytidylyl transferase, increases the discriminatory ability of the...