نتایج جستجو برای: isodose curve

تعداد نتایج: 128917  

2004
Janusz Skowronek Grzegorz Zwierzchowski Tomasz Piotrowski

Pulsed Dose Rate (PDR) treatment is a new brachytherapy modality that combines physical advantages of high-dose-rate (HDR) technology (isodose optimization and radiation safety) with radiobiological advantages of low-dose-rate (LDR) brachytherapy. Pulsed brachytherapy uses a stronger radiation source than that employed in LDR brachytherapy and provides a series of short 10 to 30 minutes long ex...

2009
Zhigang Xu Sarah E. Walsh Tejas P. Telivala Allen G. Meek Guozhen Yang

Varian Medical Systems (Palo Alto, CA) has implemented the Monte Carlo electron dose calculation algorithm (eMC) in the Eclipse treatment planning system. Previous algorithms for electron treatment planning were limited in their calculation ability for small field depth doses and monitor units. An old rule of thumb to approximate the limiting cutout size for an electron field was determined by ...

Journal: :International journal of radiation oncology, biology, physics 2011
Alexei Trofimov Paul L Nguyen Jason A Efstathiou Yi Wang Hsiao-Ming Lu Martijn Engelsman Scott Merrick Chee-Wai Cheng James R Wong Anthony L Zietman

PURPOSE To quantify daily variations in the anatomy of patients undergoing radiation therapy for prostate carcinoma, to estimate their effect on dose distribution, and to evaluate the effectiveness of current standard planning and setup approaches employed in proton therapy. METHODS We used series of computed tomography data, which included the pretreatment scan, and between 21 and 43 in-room...

2014
KR Muralidhar Birendra Kumar Rout Adavala Mallikarjuna A Poornima P Narayana Murthy

Purpose: The authors report comprehensive commissioning and quality assurance (QA) procedures for Intrabeam, Intra-Operative radiotherapy (IORT) unit. The Intrabeam system miniature X-ray source is a 50 kV and 40 μA unit. Methods: The authors’ tests include measurements of output, beam deflection, isotropy, kVp and mAs measurements, quality index, isodose, reproducibility, linearity, depth dose...

2003
Q.‐R. Jackie Wu B. W. Wessels D. B. Einstein R. J. Maciunas E. Y. Kim T. J. Kinsella

In radiosurgery, conformity indices are often used to compare competing plans, evaluate treatment techniques, and assess clinical complications. Several different indices have been reported to measure the conformity of the prescription isodose to the target volume. The PITV recommended in the Radiation Therapy Oncology Group (RTOG) radiosurgery guidelines, defined as the ratio of the prescripti...

2016
Mahdi Bakhshabadi Mahdi Ghorbani Mohsen Khosroabadi Courtney Knaup Ali S. Meigooni

PURPOSE Low energy sources are routinely used in prostate brachytherapy. (125)I is one of the most commonly used sources. Low energy (131)Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of (125)I, (103)Pd, and (131)Cs sources in interstitial brachytherapy of prostate. MATERIAL AND METHODS ProstaSeed (125)I brachytherapy sourc...

2006
Ivan A. Brezovich Richard A. Popple Jun Duan

A method is proposed for generating dynamic wedges spanning the entire field width, defined as the collimator opening in the wedged direction, without changes to existing hardware. The technique approximates the fluence pattern of a dynamic wedge by sequentially closing the leaves of a 120-leaf multileaf collimator (MLC). Closure times for the individual leaves were derived by extending the seg...

Journal: :The British journal of radiology 2014
Q Zhang D Zheng Y Lei B Morgan J Driewer M Zhang S Li S Zhou W Zhen R Thompson A Wahl C Lin C Enke

OBJECTIVE A new dosimetric variable, dose-dropping speed (DDS), was proposed and used to evaluate normal tissue sparing among stereotactic radiosurgery (SRS) plans with different prescription isodose lines. METHODS 40 plans were generated for 8 intracranial SRS cases, prescribing to isodose levels (IDLs) ranging from 50% to 90% in 10% increments. Whilst maintaining similar coverage and confor...

2010
Janusz Skowronek

Pulsed dose rate (PDR-BT) treatment is a brachytherapy modality that combines physical advantages of high-dose-rate (HDR-BT) technology (isodose optimization, radiation safety) with the radiobiological advantages of low-dose-rate (LDR-BT) brachytherapy. Pulsed brachytherapy consists of using stronger radiation source than for LDR-BT and producing series of short exposures of 10 to 30 minutes in...

Journal: :Medical physics 2000
P J Keall J V Siebers R Jeraj R Mohan

Monte Carlo dose calculations will potentially reduce systematic errors that may be present in currently used dose calculation algorithms. However, Monte Carlo calculations inherently contain random errors, or statistical uncertainty, the level of which decreases inversely with the square root of computation time. Our purpose in this study was to determine the level of uncertainty at which a lu...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید