نتایج جستجو برای: ion detection

تعداد نتایج: 762730  

Journal: :Physica Scripta 2021

Abstract We present different methods of unsupervised learning which can be used for outlier detection in high energy nuclear collisions. This method is particular interest heavy ion collisions where a direct comparison experimental data to model simulations often ambiguous and it not easy determine whether an observation due new physics, incomplete understanding the known physics or artefact. ...

Journal: :Food Hygiene and Safety Science (Shokuhin Eiseigaku Zasshi) 1983

2010
I. S. Krull

Conventional high performance 1 i qu i d chromatography instrumentation and packing materials can be inexpensively and rapidly utilized for the qualitative and quantitative analysis of various metal cations or anions. The final approaches utilize reversed phase HPLC in the form of paired-ion separations. The detection of individually eluted, fully resolved metal cations or anions is possible co...

A new azo-azomethine chemosensor containing active phenolic sites, H2L, has been designed and synthesized for rapid detection of inorganic fluoride over the other anions, such as Clˉ, Brˉ, Iˉ, AcOˉ, H2PO4ˉ, NO3ˉ, N3ˉ in DMSO/water (90/10) media. The 1H NMR titration revealed that the colorimetric response was considered to be the direct consequence of hydrogen-bond formation between phenolic gr...

Journal: :The Astrophysical Journal 2013

2014
C. Andreoiu J. Dilling D. Frekers

A novel in-trap decay spectroscopy facility has been developed and constructed for use with TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN). This apparatus consists of an open-access spectroscopy ion-trap, which is surrounded radially with up to seven low-energy planar Si(Li) detectors. The ion-trap environment allows for the detection of low-energy photons by providing backing-free st...

2013
Matthew A. Lauber Stephan M. Koza Kenneth J. Fountain

■ ■ CSH130 C18 is QC tested with a tryptic digest of cytochrome c IN T RODUC T ION Peptide mapping of a biopharmaceutical, when employed for quality control, has traditionally involved detection by UV absorbance. However, to characterize the species in a peptide map, LC separations often must be coupled with ESI-MS. Mobile phases containing trifluoroacetic acid (TFA) have been almost exclusivel...

2015
Xing-Xing Wu Chenggui Yao Jianwei Shuai

Some neuronal receptors perceive external input in the form of hybrid periodic signals. The signal detection may be based on the mechanism of vibrational resonance, in which a system's response to the low frequency signal can become optimal by an appropriate choice of the vibration amplitude of HFS. The vibrational resonance effect is investigated in a neuron model in which the intra- and extra...

2016
Adam W. Bushmaker Vanessa Oklejas Don Walker Alan R. Hopkins Jihan Chen Stephen B. Cronin

Single-ion detection has, for many years, been the domain of large devices such as the Geiger counter, and studies on interactions of ionized gasses with materials have been limited to large systems. To date, there have been no reports on single gaseous ion interaction with microelectronic devices, and single neutral atom detection techniques have shown only small, barely detectable responses. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید