نتایج جستجو برای: iol exposure
تعداد نتایج: 309395 فیلتر نتایج به سال:
PURPOSE To compare objective and subjective accommodation and visual acuities with a new accommodative intraocular lens (IOL) (Lumina; AkkoLens Clinical BV, Rijswijk, The Netherlands) with a monofocal IOL and young phakic eyes. METHODS In this prospective, randomized controlled clinical investigation, patients aged 51 to 85 years with symptomatic cataract were enrolled in the study. A total o...
PURPOSE To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. METHODS Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refract...
Purpose The purpose of this study is to evaluate effects of vitrectomy (PPV) and lens extraction with intraocular lens implantation (PE/IOL) on molecular oxygen (pO2) distribution, aqueous humor antioxidant-oxidant balance, aqueous humor dynamics, and histopathologic changes in the trabecular meshwork (TM) in the older macaque monkey. Methods Six rhesus monkeys underwent PPV followed by PE/IO...
OBJECTIVES To examine interhospital variation in rates of induction of labour (IOL) to identify potential targets to reduce high rates of practice variation. DESIGN Population-based record linkage cohort study. SETTING New South Wales, Australia, 2010-2011. PARTICIPANTS All women with live births of ≥24 weeks gestation in 72 hospitals. PRIMARY OUTCOME MEASURE Variation in hospital IOL r...
PURPOSE To compare the optical performance of 6 presbyopia-correcting intraocular lenses (IOLs) of different designs (accommodating or multifocal and aspheric or spheric). SETTING Alcon Laboratories, Inc., Fort Worth, Texas, USA. METHODS The optical performance of 6 IOLs were compared using modulation transfer function (MTF) and the United States Air Force 1951 Resolution Target (AFT) testi...
BACKGROUND To report two cases of Descemet Membrane Endothelial Keratoplasty (DMEK) in patients with existing scleral-fixated and iris-fixated intraocular lenses (sf-IOL and if-IOL, respectively). CASE PRESENTATION DMEK procedures were performed on a 49-year-old woman with a pre-existing sf-IOL (case 1) and a 69-year-old woman with a pre-existing if-IOL (case 2) in order to treat secondary co...
PURPOSE The purpose of this study was to provide clinical outcomes data related to secondary intraocular lens (IOL) implantation for the correction of residual refractive error after cataract surgery. PATIENTS AND METHODS A chart review was conducted to identify all eyes implanted with the monofocal spherical or toric AddOn® secondary IOL. Data were collated from charts where uncomplicated in...
OBJECTIVE We retrospectively analyzed the visual results and postoperative complications associated with severely traumatized eyes in which aphakia was corrected with epikeratophakia or a sutured iris prosthesis/intraocular lens (IOL). METHODS Fourteen eyes (14 patients) with traumatic aphakia and severe anterior segment complications were corrected either with epikeratophakia or a sutured ir...
PURPOSE To compare the rotational stability and posterior capsule opacification (PCO) rate in eyes with a 1-piece or 3-piece acrylic intraocular lens (IOL). SETTING Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. DESIGN Prospective randomized masked clinical trial. METHODS Patients with age-related cataract received a plate-haptic acrylic IOL (Acri.Smart 46S) i...
AIMS To compare optotype acuities and re-operation rates in children corrected with a contact lens (CL) compared with an intraocular lens (IOL) following unilateral cataract extraction during infancy in a non-randomised, retrospective case series. METHODS 25 infants with a unilateral congenital cataract underwent cataract surgery with (IOL group, n = 12) or without (CL group, n = 13) IOL impl...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید