نتایج جستجو برای: iodide ion selective electrode
تعداد نتایج: 461721 فیلتر نتایج به سال:
In this work, the results concerning to the mean activity coefficient measurements for NaCl in the (glycerol + water) system using the potentiometric method are reported. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type: Ag|AgCl|NaCl (m), glycerol (wt%), H2O (1 - wt)%|Na-ISE, in various mixed solvent systems containing 0, 5, 10,...
A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...
چکیده ندارد.
A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...
Introduction A number of works on cationic sensors have been reported in literatures [1] but less attention has been given towards the development of anionic sensors though there is a need for analysis of varieties of anions in different environmental, biomedical, industrial as well as chemical samples[2-3]. Anion sensors are simple, low cost, convenient, portable and provide quick response tow...
a new polyvinyl choloride (pvc) membrane sensor for cerium (iii) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22dd) as an ionophore. the sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1m, with a nernstian slope of 18.0±1.0 mv/decade, and a detection limit of 9.7×10-7m. it has a fast response time (5 s) and can be used for two mont...
fabrication of a cysteamine (ca) self-assembled monolayer (sam) modified gold electrode insitufunctionalized with l-lysine (lys) is presented and described. the fabricated electrode was used forhighly selective and sensitive accumulation and the determination of copper ions (cu2+) in a nanomolarconcentration. techniques like cyclic voltammetry (cv) and electrochemical impedance spectroscopy (ei...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید