نتایج جستجو برای: iodide ion selective electrode

تعداد نتایج: 461721  

In this work, the results concerning to the mean activity coefficient measurements for NaCl in the (glycerol + water) system using the potentiometric method are reported. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type: Ag|AgCl|NaCl (m), glycerol (wt%), H2O (1 - wt)%|Na-ISE, in various mixed solvent systems containing 0, 5, 10,...

E. Baghdar M. Darvishpour M.H. Fekri

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه ولی عصر (عج) - رفسنجان - دانشکده علوم 1386

چکیده ندارد.

Journal: :Journal of Automatic Chemistry 1991

A. Islamnezhad E. D. Zobairi Sh. Keyvan,

A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...

2014
Armila Rajbhandari Krishna Manandhar Raja Ram Pradhananga

Introduction A number of works on cationic sensors have been reported in literatures [1] but less attention has been given towards the development of anionic sensors though there is a need for analysis of varieties of anions in different environmental, biomedical, industrial as well as chemical samples[2-3]. Anion sensors are simple, low cost, convenient, portable and provide quick response tow...

Journal: :international journal of heterocyclic chemistry 0
fariba mehranfar department of chemistry, ahvaz branch, islamic azad university, ahvaz, iran arezoo ghaemi department of chemistry, ahvaz branch, islamic azad university, ahvaz, iran haman tavakkoli department of chemistry, ahvaz branch, islamic azad university, ahvaz, iran

a new polyvinyl choloride (pvc) membrane sensor for cerium (iii) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22dd) as an ionophore. the sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1m, with a nernstian slope of 18.0±1.0 mv/decade, and a detection limit of 9.7×10-7m. it has a fast response time (5 s) and can be used for two mont...

Journal: :iranian journal of science and technology (sciences) 2009
m. saber tehrani

fabrication of a cysteamine (ca) self-assembled monolayer (sam) modified gold electrode insitufunctionalized with l-lysine (lys) is presented and described. the fabricated electrode was used forhighly selective and sensitive accumulation and the determination of copper ions (cu2+) in a nanomolarconcentration. techniques like cyclic voltammetry (cv) and electrochemical impedance spectroscopy (ei...

Journal: :Chemistry Journal of Moldova 2010

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید