نتایج جستجو برای: inlet air cooling
تعداد نتایج: 262016 فیلتر نتایج به سال:
The performance of the adsorption cooling system is assessed in terms of the heat transfer coefficients of adsorbent bed heat exchanger. These parameters in-turn determine the specific cooling capacity (SCC) and the coefficient of the performance (COP) of the adsorption cooling system. It was observed that the overall heat transfer coefficients of the heat exchanger have a direct linear relatio...
In this study, the Li-ion batteries temperature increase during the discharge process was measured empirically and evaluated using numerical simulation. Moreover, the battery packs cooling using the water, air and water-nano composition fluids such as water-alumina, water-copper oxide, and water-gold was studied through numerical simulation. Accordingly, the battery cooling was simulated by CFD...
the aim of this study was to evaluate the effect of evaporative media as gas turbine intake air cooling method on pressure drop of cartridge air filters. this study performed under the laboratory condition, using stainless steel test rig with specified dimensions to investigate the role of evaporative media in air cooling as well as its effects on new and used cartridge filters (as representati...
Nonuniformity of inlet temperatures often produces “false-positives” that will increase overall supply airflow (higher fan energy). Nonuniformity could also result in cooler supply temperatures (lower chiller efficiency). And if you use nonuniform control mechanisms, you will not be able to target cooling where it is needed, which means you will probably overcool servers that don’t need the coo...
This study investigates the effect of air inlet size on (i) the flowfield generated in a dry powder inhaler, and (ii) the device-specific resistance, and the subsequent effect on powder deagglomeration. Computational fluid dynamics (CFD) analysis was used to simulate the flowfield generated in an Aerolizer with different air inlet sizes at 30, 45, and 60 l/min. Dispersion performance of the mod...
Heat rejection from electronic components by heat sink is still a viable cooling solution. The optimal design enables higher transfer performance. purpose of the present study to predict effectiveness elliptical closely spaced fins subjected impinging air cooling. fan main source air, then its position and direction with take role in work. Two positions location are studied. first where outside...
Three commercially available microclimate cooling systems were evaluated for their ability to reduce heat stress in men exercising in a hot environment while wearing high insulative, low permeability clothing. Five male volunteers performed three 180-min experiments (three repeats of 10 min rest, 50 min walking at 440 watts) in an environment of 38 degrees C dry bulb (Tdb), 12 degrees C dew poi...
Solar desiccant cooling is widely considered as an attractive replacement for conventional vapor compression air conditioning systems because of its environmental friendliness and energy efficiency advantages. The system performance of solar desiccant cooling strongly depends on the input parameters associated with the system components, such as the solar collector, storage tank and backup heat...
Prediction of the air temperature and humidity at the outlet of a cooling coil using neural networks
The main objective of this study is to predict air temperature and humidity at the outlet of a wire-on-tube type heat exchanger using neural networks. For this purpose, initially the heat exchanger was coupled to a refrigeration unit and placed in a wind tunnel. Afterwards, its performance was tested under various experimental conditions. We measured nine input parameters, namely, temperature a...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید