نتایج جستجو برای: implantable cardioverter defibrillator

تعداد نتایج: 19988  

Journal: :Interactive CardioVascular and Thoracic Surgery 2013

Journal: :Revista espanola de cardiologia 2014
Javier Alzueta Alonso Pedrote Ignacio Fernández Lozano

INTRODUCTION AND OBJECTIVES To present the findings of the Spanish Implantable Cardioverter-defibrillator Registry for 2013 compiled by the Electrophysiology and Arrhythmias Section of the Spanish Society of Cardiology. METHODS Prospective data were voluntarily recorded on a data collection form and sent to the Spanish Society of Cardiology by each implantation team. RESULTS Overall, 4772 d...

Journal: :Circulation 2005
Nicolas Sadoul Ralph Mletzko Frédéric Anselme Robert Bowes Wolfgang Schöls Claude Kouakam Gaëlle Casteigneau Raffaele Luise Nicolas Iscolo Etienne Aliot

BACKGROUND This study aims to assess the incidence and clinical relevance of slow ventricular tachycardia (VT) and the effectiveness and/or deleterious effects of antitachycardia pacing in slow VT in implantable cardioverter-defibrillator recipients. METHODS AND RESULTS This multicenter prospective randomized study included 374 patients (326 men) without prior history of slow VT (<148 bpm) im...

Journal: :Circulation. Arrhythmia and electrophysiology 2015
Stefano Bianchi Pietro Rossi Patrick Schauerte Arif Elvan Carina Blomström-Lundqvist Lilian Kornet Pim Gal David Mörtsell Griet Wouters Christopher Gemein

BACKGROUND Patients with a high ventricular rate during atrial fibrillation (AF) are at increased risk of receiving inappropriate implantable cardioverter defibrillator shocks. The objective was to demonstrate the feasibility of high frequency atrioventricular-nodal stimulation (AVNS) to reduce the ventricular rate during AF to prevent inappropriate implantable cardioverter defibrillator shocks...

Journal: :Journal of the American College of Cardiology 2012

Journal: :African health sciences 2012
F Ertas H Acet H Kaya F Kayan S Soydinc

Like any other foreign bodies, implanted cardiac devices can become infected. Staphylococcus aureus and coagulase-negative Staphilococci are the most common causes of infections of pacemaker and defibrillator systems. In this case an implantable cardioverter defibrillator pocket infection caused by an extremely rare microorganism, Klebsiella pneumonia, is presented.

2011
Marco Brieda Luca De Mattia Ermanno Dametto Federica Del Bianco Gianluigi Nicolosi

Upgrading of a pacing system in the presence of a subclavian occlusion is technically challenging. We describe the case of a patient who underwent a successful upgrading procedure of an implantable cardioverter-defibrillator (ICD) to a biventricular defibrillator (ICD-CRT) in the presence of a suboccluded left subclavian vein, using a collateral vein that drained into the contralateral subclavi...

Journal: :Circulation 2008
William H Maisel Daniel B Kramer

Implantable cardioverter-defibrillators (ICDs) have revolutionized the treatment of patients at risk for sudden cardiac death. In the nearly 3 decades since the first human ICD implant,1 millions of devices have been implanted worldwide and innumerable lives have been saved. Successful resuscitation of a potentially lethal ventricular arrhythmia by an ICD system depends on successful arrhythmia...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید