نتایج جستجو برای: hotellings t2

تعداد نتایج: 30671  

Journal: :Magnetic resonance in medicine 2014
Mehmet Akçakaya Tamer A Basha Sebastian Weingärtner Sébastien Roujol Sophie Berg Reza Nezafat

PURPOSE To develop an improved T2 prepared (T2 prep) balanced steady-state free-precession (bSSFP) sequence and signal relaxation curve fitting method for myocardial T2 mapping. METHODS Myocardial T2 mapping is commonly performed by acquisition of multiple T2 prep bSSFP images and estimating the voxel-wise T2 values using a two-parameter fit for relaxation. However, a two-parameter fit model ...

2016
Mohammed H. Alam Taigang He Dominique Auger Gillian C. Smith Peter Drivas Rick Wage Cemil Izgi Karen Symmonds Andreas Greiser Bruce S. Spottiswoode Lisa Anderson David Firmin Dudley J. Pennell

BACKGROUND There is a need for improved worldwide access to tissue iron quantification using T2* cardiovascular magnetic resonance (CMR). One route to facilitate this would be simple in-line T2* analysis widely available on MR scanners. We therefore compared our clinically validated and established T2* method at Royal Brompton Hospital (RBH T2*) against a novel work-in-progress (WIP) sequence w...

2015
Bettina Baeßler Frank Schaarschmidt Christian Stehning Bernhard Schnackenburg David Maintz Alexander C. Bunck

BACKGROUND The aim of this study was the evaluation of a fast Gradient Spin Echo Technique (GraSE) for cardiac T2-mapping, combining a robust estimation of T2 relaxation times with short acquisition times. The sequence was compared against two previously introduced T2-mapping techniques in a phantom and in vivo. METHODS Phantom experiments were performed at 1.5 T using a commercially availabl...

Journal: :Journal of magnetic resonance imaging : JMRI 2015
Di Xu Daniel A Herzka Wesley D Gilson Elliot R McVeigh Jonathan S Lewin Clifford R Weiss

PURPOSE Image-guided treatment of low-flow vascular (venous or lymphatic) malformations presents a challenging visualization problem, regardless of the imaging modality being used for guidance. The purpose of this study was to employ a new magnetic resonance imaging (MRI) sequence, T2 -weighted interrupted balanced steady-state free precession (T2 W-iSSFP), for real-time image guidance of needl...

Journal: :The Journal of clinical investigation 1980
J Faber O K Faber B Lund C Kirkegaard J Wahren

The sequential deiodination of thyroxine (T4) gives rise to several iodothyronine analogs including 3,3'-diiodothyronine (3,3'-T2) and 3',5'-diiodothyronine (3',5'-T2). In vitro animal studies suggest that the liver and the kidneys are the main sites of both formation and degradation of 3,3'-T2 and 3',5'-T2. To determine the metabolism of 3,3'-T2 and 3',5'-T2 in human liver and kidneys plasma s...

2008
A. S. Fairchild J. Croom J. L. Grimes W. M. Hagler

The objectives of this study were: 1) to examine effects of a dietary sodium bentonite, ASTRABEN–20 (AB20) [Prince Agri Products, Inc., Quincy, Ill.], on in vitro binding of T2 toxin and aflatoxin B (AFB1); ® 1 and 2) to examine the effects of AB20 in broiler chicks fed 6 ppm dietary T2 toxin (T2) or 4 ppm aflatoxin B1 (AFB1) to 21 d. Day-old male broiler chicks were randomly placed in batterie...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید