نتایج جستجو برای: heterogeneous slab phantom

تعداد نتایج: 152537  

2017
Michele Paulatto Mireille Laigle Audrey Galve Philippe Charvis Martine Sapin Gaye Bayrakci Mikael Evain Heidrun Kopp

Subducting slabs carry water into the mantle and are a major gateway in the global geochemical water cycle. Fluid transport and release can be constrained with seismological data. Here we use joint active-source/local-earthquake seismic tomography to derive unprecedented constraints on multi-stage fluid release from subducting slow-spread oceanic lithosphere. We image the low P-wave velocity cr...

Journal: :Magnetic resonance imaging 2006
David Alberg Holm Karam Sidaros

OBJECTIVE An important source of error in arterial spin labeling (ASL) is incomplete static tissue subtraction due to imperfect slice profiles. This effect can be reduced by saturating the spins in the imaging area prior to labeling. In this study, the use of optimized presaturation is compared with the use of optimized RF pulses for minimizing this error. MATERIALS AND METHODS Different meth...

Journal: :Physics in medicine and biology 2011
Melanie Freed Andreu Badal Robert J Jennings Hugo de las Heras Kyle J Myers Aldo Badano

The purpose of this study is to characterize the x-ray properties of a dual-modality, anthropomorphic breast phantom whose MRI properties have been previously evaluated. The goal of this phantom is to provide a platform for optimization and standardization of two- and three-dimensional x-ray and MRI breast imaging modalities for the purpose of lesion detection and discrimination. The phantom is...

2011
Indra J. Das Minsong Cao Chee‐Wai Cheng Vladimir Misic Klaus Scheuring Edmund Schüle Peter A.S. Johnstone

Electronic portal imaging device (EPID) plays an important role in radiation therapy portal imaging, geometric and dosimetric verification. Consistent image quality and stable radiation response is necessary for proper utilization that requires routine quality assurance (QA). A commercial 'EPID QC' phantom weighing 3.8 kg with a dimension of 25 × 25 × 4.8 cm³ is used for EPID QA. This device ha...

Journal: :Magnetic resonance in medicine 2004
C Stehning P Börnert K Nehrke H Eggers O Dössel

A shortcoming of current coronary MRA methods with thin-slab 3D acquisitions is the time-consuming examination necessitated by extensive scout scanning and precise slice planning. To improve ease of use and cover larger parts of the anatomy, it appears desirable to image the entire heart with high spatial resolution instead. For this purpose, an isotropic 3D-radial acquisition was employed in t...

Asghar Mesbahi, H. Dadgar,

Background: Accurate dose calculations in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS).  In the current study, the dose calculation accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calculations. Materials and Methods: The head of Siemens Oncor-impression linac...

Mahmoud Allahverdi Mohammad Hasan Zahmatkesh Tayeb Allahverdi Pourfallah,

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

2008
Vicente Abella Rafael Miró Belén Juste Gumersindo Verdú

The purpose of this work is to obtain the voxelization of a series of tomography slices in order to provide a voxelized human phantom throughout a MatLab algorithm, and the consequent simulation of the irradiation of such phantom with the photon beam generated in a Theratron 780® (MDS Nordion) 60 Co radiotherapy unit, using the Monte Carlo transport code MCNP (Monte Carlo N-Particle), version 5...

2016
Krystian Skubacz

The appropriate evaluation of measured doses in mixed fi elds requires the calibration of dosimeters in relation to different types of radiation and exposure conditions in order to split the signal into individual components corresponding to the specifi c radiation and exposure conditions of the entire period and evaluate the critical level, lower limit of detection and corresponding uncertaint...

Journal: :international journal of iron & steel society of iran 2007
a. saboonchi a. h. meghdadi

obtaining temperature distribution data of slabs under rolling is essential as the mechanical and metallurgical properties of the metal under this process vary with temperature. using the control volume method, a mathematical model is employed in this study to predict slab temperature in the hot roll process at mobarakeh steel company. the effects of different parameters including the heat resu...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید