نتایج جستجو برای: heating and cooling systems
تعداد نتایج: 17000165 فیلتر نتایج به سال:
In this study, the effect off adding SiO2 nanoparticles on the viscosity of base fluid is investigated experimentally. Base fluids are chosen among common heat transfer fluids such as ethylene glycol, transformer oil and water. In addition different volume percentages of ethylene glycol in water are used as ethylene glycol-water solution. In every base fluid different volume fractions of SiO2 n...
Abstract: Naval surface ships should use thermally driven heating and cooling technologies to continue the Navy’s leadership role in protecting the marine environment. Steam ejector refrigeration (SER) or steam ejector heat pump (SEHP) systems are thermally driven heating and cooling technologies and seem to be a promising technology to reduce emissions for heating and cooling on board naval su...
temperature restrictions on aqueous effluents dictate that streams with a temperature higher than the permitted level needed to pass through cooling systems to reduce the effluent temperature before discharge. in this study, by considering the grouping design rules based on pinch technology, an optimum design for a distributed effluent cooling system, has been developed. a counter-flow wet cool...
introduction reducing and optimizing energy consumption and consequently environmental pollution reductions, besides improving building performance providing occupants comfort conditions, make the building's concept closer to the concept of green building and sustainability. once the decision to build green has been made, one of the first steps in the green design process is to establish f...
In the present study, performance analysis of a multi effect distillation with thermo vapor compressor (MED-TVC) desalination system coupled to a combined cooling, heating and power (CCHP) system with gas turbine prime mover has been carried out to cogeneration of cooling, heating, power and potable water. The system incorporates air compressor, combustion chamber, gas turbine, triple pressure ...
Laboratory measurements on polymer raw materials and products are often carried out (quasi-) isothermally, or at best at relatively slow cooling and heating rates. Such conditions differ greatly from those occurring during processing and during the products use in real life. During processing, high cooling rates and high pressures are common, the parameters of which have a major influence on t...
An in vitro preparation of the guinea-pig cornea was used to study the effects of changing temperature on nerve terminal impulses recorded extracellularly from cold-sensitive receptors. At a stable holding temperature (31-32.5 degrees C), cold receptors had an ongoing periodic discharge of nerve terminal impulses. This activity decreased or ceased with heating and increased with cooling. Reduci...
A wind tunnel conditions the air flow for testing equipment, such as heat exchangers, over a wide range of conditions. In this paper, a procedure to develop the operating envelope for the tested equipment in a wind tunnel is presented. The temperature and humidity of the air that requires conditioning is controlled and maintained by the combination of cooling coil (or evaporator), heating eleme...
STATEMENT OF PROBLEM Porcelain fused to zirconia prostheses are widely used. However, porcelain chipping, spalling, fracture, and delamination are common clinical problems. Residual stresses of thermal origin have received attention, but clear data and firing guidelines remain absent. PURPOSE The purpose of this study was to measure the influence of heating and cooling protocols on the streng...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید