نتایج جستجو برای: gas turbine starter

تعداد نتایج: 267319  

2012
Jeffrey A. Dixon Antonio Guijarro Valencia

This paper summarises the work of a 5-year research programme into the heat transfer within cavities adjacent to the main annulus of a gas turbine. The work has been a collaboration between several gas turbine manufacturers, also involving a number of universities working together. The principal objective of the study has been to develop and validate computer modelling methods of the cooling fl...

2014
Chad M. Holcomb Raymond A. de Callafon Robert R. Bitmead

Many practical applications, such as the fuel control of a gas turbine engine, can be modeled by a feedback connection of a linear controller in series with a Hammerstein system, where the nonlinearity provides a representation of the control element or actuator. An iterative gradient-based method is proposed to simultaneously identify the nonlinear fuel valve characteristic and a low-order lin...

2013
V. Gopinath

Performance of a gas turbine is mainly depends on the inlet air temperature. The power output of a gas turbine depends on the mass flow rate of air. Now days the atmosphere temperature is hot, so the air is less density, the mass flow rate will reduce and automatically the power output will reduce. A reduce of 1°C temperature of inlet air increases the power output by approximately 0.7MW. To re...

2010
Shinji KIMIJIMA Nobuhide KASAGI

マイク ロガスター ビン ・固体酸化物形燃料電池 ハ イブ リッ ドシステムの部分負荷特性の評価* 君 島 真 仁*1, 笠 木 伸 英*2 Performance Evaluation of Micro Gas Turbine-Solid Oxide Fuel Cell Hybrid System under Part-Load Conditions Shinji KIMIJIMA*3 and Nobuhide KASAGI *3 Department of Machinery and Control Systems, Shibaura Institute of Technology, 307 Fukasaku, Minuma-ku, Saitama-shi, Saitama, 337-8570 Japan Design-point and part-load characteri...

2002
M. A. Paisley R. P. Overend

The Burlington, Vermont gasifier is the first commercial scale demonstration of Future Energy Resources SilvaGas biomass gasification process. The gasification plant is the largest operation of its type in the United States. The Burlington plant is coupled to the McNeil station of the Burlington Electric Department and is being used to evaluate and demonstrate the gasification technology both a...

2013
Ameneh Vatani

Degradation Prognostics in Gas Turbine Engines Using Neural Networks

2015
A. V. Krivcov O. V. Baturin

The aim of this article was the development of the gas-dynamic models allowing to calculate the working processes of the gas turbine engine (GTE) in the compressor, in the combustion chamber and in the turbine at the same time. The possibilities of software systems for complex engine workflow modeling are specified. The advantages and disadvantages of the presented methods are specified. The re...

Journal: :international journal of occupational hygiene 0
ali karimi occupational health department, school of public health and nutrition, shiraz university of medical sciences, shiraz, iran and occupational health eng. department, school of public health, tehran university of medical sciences, tehran, iran. farideh golbabaei occupational health eng. department, school of public health, tehran university of medical sciences, tehran, iran. mohammadreza mehrnia biotechnology group, school of chemical engineering, university college of engineering, university of tehran, tehran, iran. kazem mohammad epidemiology and biostatistics department, school of public health, tehran university of medical sciences, tehran, iran. masoud neghab occupational health department, school of public health and nutrition, shiraz university of medical sciences, shiraz, iran. ahmad nikpey occupational health department, school of public health, qazvin university of medical sciences, qazvin, iran.

a laboratory stirred tank bioreactor with six single and dual-impeller configurations was tested to obtain the optimum operating conditions for future biological processes. six impeller combinations consisting of three basic impeller types, namely rushton turbine (rt), pitched 4blade (p4b) and pitched 2blade (p2b) downward flow were investigated in 1.77 l bioreactor working volume. power consum...

2016
Hyung Hee Cho

Abstract—There is a gap at combustor-turbine interface where leakage flow comes out to prevent hot gas ingestion into the gas turbine nozzle platform. The leakage flow protects the nozzle endwall surface from the hot gas coming from combustor exit. For controlling flow’s stream, the gap’s geometry is transformed by changing fillet radius size. During the operation, step configuration is occurre...

2010
T. S. Dhanasekaran Ting Wang

To achieve higher efficiency target of the advanced turbine systems, the closed-loop steam cooling scheme is employed to cool the airfoil. It is proven from the experimental results at laboratory working conditions that injecting mist into steam can significantly augment the heat transfer in the turbine blades with several fundamental studies. The mist cooling technique has to be tested at gas ...

نمودار تعداد نتایج جستجو در هر سال