نتایج جستجو برای: finite element method retrofitting reinforced concrete beam steel

تعداد نتایج: 2161972  

Precast prestreesed concrete braces are a new method for seismic strength of Concrete Structures which has the following benefits: a) no wet concrete work in construction site b) No bolt or anchorage to the existing frame c) easy to apply d) short construction period e) low construction cost, to evaluate seismic performance of strengthened structure a model consist of existing frame and concret...

2017
Muhammad N. S Hadi

The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection is a T connection representing a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised st...

2008
Cenk Tort Jerome F. Hajjar

A comprehensive computational model to simulate the nonlinear seismic response of composite frames with rectangular concrete-filled steel tube (RCFT) beam-columns and steel girders and braces is presented in this work. A three-dimensional fiber-based distributed plasticity mixed finite element formulation is introduced. The finite element formulation of RCFT beam-columns was derived with separa...

2015
T. R. Sethuraman

Retrofitting works are immensely essential for deteriorated and damaged structures in Engineering and Medical fields, in order to keep, or return to, the originality for safe guarding the structures and consumers. In this paper, different types of methods of retrofitting review notes are given based on the experimental, numerical and analytical methods results on strengthening the Reinforced ce...

Journal: :Buildings 2023

This study investigates the behavior of three concrete beams reinforced with steel and GFRP bars under fire exposure. The tests were conducted including one control steel-reinforced (RC) beam two GFRP-RC beams. exposed to according standard curve ISO 834 for 3 h. investigation parameters included reinforcement types (i.e., bars) diameter bars. Based on experimental results, during exposure, def...

2009
F. Hejazi J. Noorzaei M. S. Jaafar A. A. Abang

This paper describes the development of a numerical finite element algorithm used for the analysis of reinforced concrete structure equipped with shakes energy absorbing device subjected to earthquake excitation. For this purpose a finite element program code for analysis of reinforced concrete frame buildings is developed. The performance of developed program code is evaluated by analyzing of ...

2014
Zhupeng Zheng Ying Lei Xin Xue

Numerical simulation based on finite element method is conducted to predict the location of pitting corrosion in reinforced concrete. Simulation results show that it is feasible to predict corrosion monitoring based on ultrasonic guided wave in reinforced concrete, and wavelet analysis can be used for the extremely weak signal of guided waves due to energy leaking into concrete. The characteris...

This paper deals with the modeling of punching shear failure in reinforced concrete slabs using nonlinear finite element analysis. The 3D finite element analyses (FEA) were performed with the appropriate modeling of element size and mesh, and the constitutive modeling of concrete. The FE numerical models are validated by comparing with the experimental results obtained from tested specimens and...

2016
Omar I. Abdelkarim Mohamed A. ElGawady

This paper presents the difference in behavior between hollow-core fiber reinforced polymer-concrete-steel (HC-FCS) columns and conventional reinforced concrete (RC) columns under vehicle collision in terms of dynamic and static forces. The HC-FCS column consisted of an outer FRP tube, an inner steel tube, and a concrete shell sandwiched between the two tubes. The steel tube was hollow inside a...

2017
Muhammad N. S Hadi

The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection represents a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised steel straps were used...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید