نتایج جستجو برای: film dosimeter
تعداد نتایج: 92845 فیلتر نتایج به سال:
The research reported in this paper on the changes in absorbance and the calibration of a proposed UVA (320-400 nm) dosimeter have established the phenothiazine-mylar combination as a potential UVA dosimeter for population studies of UVA exposures. The change in optical absorbance at 370 nm was employed to quantify the UVA exposures. This change starts to saturate at a change in absorbance of a...
Purpose: To evaluate the measured dose distributions using radiochromic EBT2 films for small fields in iPlan (BrainLab) commissioning. Methods: Radiochromic EBT2 films were irradiated with 6 MV photons on a Varian Trilogy linac using polystyrene phantoms. The measurements included dose profiles and depth doses for field sizes of 1 × 1, 2 × 2, 3 × 3, 4 × 4, and 10 × 10 cm etc. The dose profile m...
Two potential sources of systematic variation in output from Mefar dosimeters, the system used in the European Community Respiratory Health Survey (ECRHS) study have been evaluated: individual nebulizer characteristics and dosimeter driving pressure. Output variation from 366 new nebulizers produced in two batches for the second ECRHS were evaluated, using a solute tracer method, at a fixed dri...
This paper explores the combination of cone beam optical computed tomography with an N-isopropylacrylamide (NIPAM)-based polymer gel dosimeter for three-dimensional dose imaging of small field deliveries. Initial investigations indicate that cone beam optical imaging of polymer gels is complicated by scattered stray light perturbation. This can lead to significant dosimetry failures in comparis...
For megavoltage photon radiation, the fundamental dosimetry characteristics of Gafchromic EBT3 film were determined in 60Co gamma ray beam with addition of experimental and Monte Carlo (MC)-simulated energy dependence of the film for 6 MV photon beam and 6 MeV, 9 MeV, 12 MeV, and 16 MeV electron beams in water phantom. For the film read-out, two phase correction of scanner sensitivity was appli...
This work examined the suitability of the PAGAT gel dosimeter for use in dose distribution measurements around high-density implants. An assessment of the gels reactivity with various metals was performed and no corrosive effects were observed. An artefact reduction technique was also investigated in order to minimise scattering of the laser light in the optical CT scans. The potential for atte...
We developed a multichannel all-in-one phantom dosimeter system composed of nine sensing probes, a chest phantom, an image intensifier, and a complementary metal-oxide semiconductor (CMOS) image sensor to measure the dose distribution of an X-ray beam used in radiation diagnosis. Nine sensing probes of the phantom dosimeter were fabricated identically by connecting a plastic scintillating fiber...
In this study the spectrophotometric response of the Toluidine Blue O (TBO)-gelatin gel dosimeter irradiated with gamma rays was characterized. Preparation of dyed-gelatin gel takes place in neutral medium; to give eventually gel dosimeter has a sharp absorbance peak at 635 nm that bleaches quantitatively upon irradiation and the colour change can be measured with UV-VIS spectrophotometer. The ...
The normoxic polymer gel dosimeter based on N-isopropyl acrylamide (NiPAM) is a promising full 3D-dosimeter with high spatial resolution and near tissue equivalency. NiPAM gel samples were irradiated to different doses using a linear accelerator. The absorbed dose was evaluated using MRI and statistical significance of the analysed data was calculated. The analysis was carried out using an in-h...
A passive dosimeter designed to measure exposure to hydrogen fluoride was tested under laboratory conditions over the concentration range of 0.56 – 4.47 mg HF/m. The lowest concentration was chosen to be close to the Polish TLV (0.5 mg HF/m). The dosimeter consists of a Whatman No.1 filter paper impregnated with K2HPO4 placed in a polyethylene holder protected by a polyethylene screen. After ex...
نمودار تعداد نتایج جستجو در هر سال