نتایج جستجو برای: femoral fixation
تعداد نتایج: 90344 فیلتر نتایج به سال:
Introduction: The indications for intramedullary nail fixation of fractures of the femoral shaft have been greatly expanded by techniques of interlocking nailing. However, distal locking screw fixation remains the most technically demanding and problematic portion of the procedure and maybe responsible for as much as one-half of the exposure of the surgeon’s hands to radiation during the proced...
BACKGROUND Hip prostheses with short anatomical stems were designed for metaphyseal fixation and to spare bone stock. We present a study of a short anatomical femoral stem used in all age groups of patients with Dorr A and B type of femora. METHODS We reviewed radiographs of 85 hips in 74 patients who had a cementless total hip arthroplasty with a short anatomical 80 mm femoral stem designed ...
External fixation can be an exceptional relief solution in the treatment of proximal femoral fractures. We would like to share our experience using external fixation techniques with either the Ilizarov frame or Hofmann system in 23 patients with complicated fractures.
Intramedullary nail fixation is the treatment of choice for impending and pathologic fractures secondary to metastatic cancer; however, this procedure has been shown to cause systemic embolization of intramedullary contents. This article reports the use of the reamer-irrigator-aspirator (RIA) (Synthes, Paoli, Pennsylvania) instead of a standard femoral reamer to decrease tumor intravasation dur...
The authors report a case of secondary femoral fracture through the sliding hip screw portal following fixation of the femoral neck fracture. The femoral neck and subtrochanteric fracture was successfully treated by superimposing a trochanteric stabilization plate (TSP) onto the regular sliding hip screw.
BACKGROUND Femoral neck fractures are urgent injuries that require precise reduction and stable fixation. In some cases, however, early treatment is not possible. OBJECTIVES The present study aimed to evaluate long-term results of delayed fixation of femoral neck fractures using cannulated screws. PATIENTS AND METHODS This retrospective descriptive-analytical study was conducted on 26 patie...
PURPOSE To biomechanically evaluate single screw and varying 2 screw fixations for an unstable slipped capital femoral epiphysis (SCFE) model using physiologically relevant loading. STUDY DESIGN In vitro biomechanical study. METHODS Twenty-four immature porcine proximal femurs were prepared to simulate a mild-to-moderate unstable SCFE. The femurs were randomized into 4 fixation groups: sing...
BACKGROUND When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described impla...
The results of meta-analysis show a revision rate of 33% for internal fixation of displaced fractures of the femoral neck, mostly because of nonunion. Osteopenia and osteoporosis are highly prevalent in elderly patients. Bone density has been shown to correlate with the intrinsic stability of the fixation of the fracture in cadaver and retrospective studies. We aimed to confirm or refute this f...
The incidence of femoral fracture on hip prosthesis is increasing. Plate fixation is the method of choice when the prosthesis is stable. In fracture with proximal extension, the quality of the bone fixation is critical and, despite the development of anatomic plates, may be endangered when there are too few proximal screws. To resolve this issue, we recommend using a reversed LCP™ anatomic dist...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید