نتایج جستجو برای: ebt2

تعداد نتایج: 128  

2015
Keyvan Jabbari Somayeh Senobari Mahnaz Roayaei Masoumeh Rostampour

The cancer of oral cavity is related to lesions of mucous membrane of tongue and gum that can be treated with radiation therapy. A lateral photon field can be used to treat this kind of tumor, which has a side-effect on normal tissue in the opposite side of the oral cavity. In this study the dosimetric effect of the various shields in oral cavity is evaluated. In this study, a special phantom s...

Journal: :Medical physics 2015
Joseph T Rakowski Suvra S Laha Michael G Snyder Matthew G Buczek Mark A Tucker Fangchao Liu Guangzhao Mao Yair Hillman Gavin Lawes

PURPOSE Bombarding high-Z material with x-ray radiation releases Auger electrons and Coster-Kronig electrons, along with deeper penetrating fluorescent x-rays and photoelectrons. The Auger and Coster-Kronig electron penetration distance is on the order of nanometers to micrometers in water or tissue, creating a large dose enhancement accompanied by a RBE greater than 1 at the cellular level. Th...

2015
Samantha A.M. Lloyd Sergei Zavgorodni Isabelle M. Gagne

Dosimetric comparisons of radiation fields produced by Varian's newest linear accelerator, the TrueBeam, with those produced by older Varian accelerators are of interest from both practical and research standpoints. While photon fields have been compared in the literature, similar comparisons of electron fields have not yet been reported. In this work, electron fields produced by the TrueBeam a...

Journal: :Medical physics 2012
D Kim I Wang

PURPOSE High atomic number (Z) materials have been considered as a method for enhancing radiation dose in tumors. The dose enhancement due to interactions of kilovoltage x-rays with high-Z materials (i.e., gold or iodine) has been well demonstrated through computational works. This study is to experimentally quantify the effect using gold nanoparticles (AuNPs) and iodine solutions, respectively...

2017
Ronghu Mao Lingling Tian You Zhang Lei Ren Renqi Gao Fang-Fang Yin Hong Ge

OBJECTIVE The objective of this study is to theoretically and experimentally evaluate the dosimetry in the microscopic disease regions surrounding the tumor under stereotactic body radiation therapy of lung cancer. METHODS For simplicity, the tumor was considered moving along 1 dimension with a periodic function. The probability distribution function of the tumor position was generated accord...

2015
Heming Zhen Brian Hrycushko Huichen Lee Robert Timmerman Arnold Pompoš Strahinja Stojadinovic Ryan Foster Steve B. Jiang Timothy Solberg Xuejun Gu

The aim of this study is to compare the recent Eclipse Acuros XB (AXB) dose calculation engine with the Pinnacle collapsed cone convolution/superposition (CCC) dose calculation algorithm and the Eclipse anisotropic analytic algorithm (AAA) for stereotactic ablative radiotherapy (SAbR) treatment planning of thoracic spinal (T-spine) metastases using IMRT and VMAT delivery techniques. The three c...

2015
Yingcui Jia Li Zhao Chee‐Wai Cheng Mark W. McDonald Indra J. Das

The purpose of this study was to investigate the effect of dose perturbations for two metallic spinal screw implants in proton beam therapy in the perpendicular and parallel beam geometry. A 5.5 mm (diameter) by 45 mm (length) stainless steel (SS) screw and a 5.5 mm by 35 mm titanium (Ti) screw commonly used for spinal fixation were CT-scanned in a hybrid phantom of water and solid water. The C...

2013
Karina P. Esparza‐Moreno Olivia A. Garcáa‐Garduño Paola Ballesteros‐Zebadúa José M. Lárraga‐Gutiérrez Sergio Moreno‐Jiménez Miguel A. Celis‐López

Trigeminal neuralgia (TN) is a chronic, episodic facial pain syndrome that can be extremely intense, and it occurs within the regions of the face that are innervated by the three branches of the trigeminal nerve. Stereotactic radiosurgery (SRS) is the least invasive procedure to treat TN. SRS uses narrow photon beams that require high spatial resolution techniques for their measurement. The use...

Journal: :Medical physics 2013
A Schoenfeld R Crilly B Poppe W Laub

PURPOSE Implants with high atomic numbers produce star-like artifacts in CT-images. When coupled in pairs, a black window appears in between. The Philips OMAR algorithm approaches these artifacts by post processing the images. In this study, measurements were performed with radiochromic EBT2 films in order to verify, whether the OMAR algorithm contributes to the accuracy of treatment plans in i...

الهویردی پورفلاح, طیب, اکبری, محمود رضا , قاسمی, آرش ,

Background and purpose: Due to creation of scattered radiation when using non-carbon fiber base plates particularly in treating breast cancer, applying this device can affect skin and body surface dose. Recently, using Gaf-Chromic films have led to obtaining good results in skin dosimetry. The purpose of this study was the estimation of skin dose in applying non-carbon fiber base plates using w...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید