نتایج جستجو برای: dosimetry linear accelerator add on mlc recommissioning

تعداد نتایج: 8622156  

2016
Alex Wells

Objectives: Developing an optimal Stereotactic radiosurgery (SRS) plan for multiple brain metastases can be a labor intensive process. Single-isocenter multi-arc volumetrically modulated arc therapy (VMAT) has been used as an SRS technique, in which a Linear Accelerator (Linac) delivers targeted radiation along multiple arc angles as it rotates around the isocenter. Standardized arc angles with...

Journal: :iranian journal of radiation research 0
f. bouzarjomehri shahid sadoughi university of medical sciences, yazd, iran m. kiani tabriz university of medical sciences, medical physics, tabriz, iran a.r. farajollahi tabriz university of medical sciences, medical physics, tabriz, iran

background: the shielding methods in radiotherapy due to delivering an accurate radiation dose to cancer tissues and avoiding unnecessary dose to normal tissues are very important. these methods include lead standard blocks, individual molding and multi leaf collimator (mlc). the mlc method is not still common in iran radiotherapy centers. individual molding is better than the lead block shield...

A.R. Farajollahi, F. Bouzarjomehri, M. Kiani,

Background: The Shielding methods in radiotherapy due to delivering an accurate radiation dose to cancer tissues and avoiding unnecessary dose to normal tissues are very important. These methods include Lead standard blocks, individual molding and multi leaf collimator (MLC). The MLC method is not still common in Iran radiotherapy centers. Individual molding is better than the lead block shield...

Journal: :iranian journal of radiation research 0
m. hajizadeh saffar medical physics department, mashhad university of medical sciences, mashhad, iran m.r. ghavamnasiri h. gholamhosseinian

background: in radiotherapy, wedge filters are used for optimizing the tumor dose distribution in patients. the attenuation in beam intensity due to the presence of wedge filter is compensated by means of a wedge factor measured at the central axis of the beam. the field size, depth and ssd dependence of wedge factor have been assessed for 9mv radiations of neptun pc linear accelerator. materia...

H. Gholamhoseinian, M. Momennezhad, M.T. Bahreyni Toosi, R. Sadeghi, Sh. Nasseri,

Background: The presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. Material and Methods: In this study the MCNP-4C Monte Carlo code was used to simulate the 9 MV photon beam generated by a linear accelerator. Upon getting a good agreement bet...

ژورنال: سنجش و ایمنی پرتو 2014

During the radiation therapy with electron beam, due to electron interaction and scattering from structures of the head of the medical linear accelerator, unwanted photons are produced. The main contribution of the photon contamination is resulted from the various components of the medical linear accelerator on the way of the high energy electron beam, and few percent is due to the interaction ...

2016
Lori A. Young Fei Yang Ning Cao Juergen Meyer

During volume-modulated arc therapies (VMAT), dosimetric errors are introduced by multiple open dynamic leaf gaps that are present in fixed diaphragm linear accelerators. The purpose of this work was to develop a methodology for adjusting the rounded leaf end modeling parameters to improve out-of-field dose agreement in SmartArc VMAT treatment plans delivered by fixed jaw linacs where leaf gap ...

2007
Jouni Uusi–Simola Sami Heikkinen Petri Kotiluoto Tom Serén Tiina Seppälä Iiro Auterinen Sauli Savolainen

Radiation sensitive polymer gels are among the most promising three-dimensional dose verification tools developed to date. Polymer gel dosimeter known by the acronym MAGIC has been tested for evaluation of its use in boron neutron capture (BNCT) dosimetry. We irradiated a large (diameter 10 cm, length 20 cm) cylindrical gel phantom in the epithermal neutron beam of the Finnish BNCT facility at ...

ژورنال: سنجش و ایمنی پرتو 2015

With the development of science and technology in the medical field and need more than ever to accuracy and quality of treatment has been causer increase different radiotherapy methods. Almost the past two decade’s intraoperative radiation therapy (IORT) as one of the new techniques used to treat cancer patients. One of the problems with this method is obtaining accurate dosimetry, becaus...

2002
Sasa Mutic Jacqueline Esthappan Eric E. Klein

The American Association of Physicists in Medicine Task Group 36 (AAPM TG-36) data can be used to estimate peripheral dose (PD) distributions outside the primary radiation field. However, the report data does not apply to linear accelerators equipped with a multileaf collimator (MLC) and universal wedge (UW). Tertiary multileaf collimators have been shown to significantly affect PD distribution...

نمودار تعداد نتایج جستجو در هر سال