نتایج جستجو برای: depth dose

تعداد نتایج: 468234  

2008
M Mokhtari-Dizaji A A Sharafi B Larijani N Mokhlesian H Hasanzadeh

OBJECTIVE The purpose of this study is to estimate a patient's organ dose (effective dose) during performance of dual X-ray absorptiometry by using the correlations derived from the surface dose and the depth doses in an anthropomorphic phantom. MATERIALS AND METHODS An anthropomorphic phantom was designed and TLDs (Thermoluminescent Dosimeters) were placed at the surface and these were also ...

Journal: :Medical physics 1997
T Aoyama S Koyama M Tsuzaka H Maekoshi

The development of a new depth-dose measuring device for electron beam therapy is described. The device employs plastic scintillating fiber detectors inserted in a polymethylmethacrylate (PMMA) phantom in line along an incident electron beam. Output photons from a fiber, the number of which is proportional to the absorbed dose at each depth of the phantom, were converted to an electric signal w...

Journal: :iranian journal of medical physics 0
mohammad javad t ahmasebi associated professor, medical physics & radiotherapy dept., golestan hospital, ahwaz university of medical sciences, ahwaz, iran mohammad ali behrooz professor, medical physics dept., ahwaz university of medical sciences, ahwaz, iran shole arvandi assistant professor, radiotherapy & oncology dept., golestan hospital, ahwaz university of medical sciences, ahwaz, iran davood khezerloo m.sc. medical physics dept., ahwaz university of medical sciences, ahwaz, iran mojtaba karbalai m.sc. medical physics dept., golestan hospital, ahwaz university of medical sciences, ahwaz, iran

introduction: nowadays,  considerable developments  in  the field  of  radiotherapy have  been  achieved.  they  include  the  advances  made  in  the  equipments  and  treatment  planning  techniques  which  require  highly complex calculations. such achievements have made it possible to treat cancer patients not only  with  higher  radiation  dose  but  also  with  higher  precision  and  con...

Journal: :iranian journal of medical physics 0
hadis ansari mehr1 department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

introduction the use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (pdd) curves. these changes and electron beam dose distribution in the form of three-dimensional (3d) can be measured by gel dosimeters. materials and methods dosimetry was performed with and without a square shield (6×6 cm2 field). the energies were 4, 9, and 16 mev and phantom w...

Introduction Evaluation of the delivered dose of externally wedged photon beams by external diode dosimeters during the treatment process requires the estimation of exit surface dose correction factors in various wedge angles and field sizes. Materials and Methods A system of absorbed dose evaluation, using p-type diode dosimeters placed on the exit surface of a phantom, was characterized for e...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سیستان و بلوچستان - دانشکده مهندسی 1392

flow in natural river bends is a complex and turbulent phenomenon which affects the scour and sedimentations and causes an irregular bed topography on the bed. for the reason, the flow hydralics and the parameters which affect the flow to be studied and understand. in this study the effect of bed and wall roughness using the software fluent discussed in a sharp 90-degree flume bend with 40.3cm ...

2012
Khosrow Javedan Geoffrey G. Zhang Sarah Hoffe Vladimir Feygelman Kenneth Forster

The build-up dose in the megavoltage photon beams can be a limiting factor in intensity-modulated radiation therapy (IMRT) treatments. Excessive surface dose can cause patient discomfort and treatment interruptions, while underdosing may lead to tumor repopulation and local failure. Dose in the build-up region was investigated for IMRT delivery with solid brass compensator technique(compensator...

Journal: :The International journal of applied radiation and isotopes 1979
P Plato

Slabs of natural and depleted uranium are used routinely to calibrate personal dosimeters and radiation survey instruments for beta radiation. However, little information is available on the absorbed dose rate produced by a uranium slab as a function of depth in matter. In this study, an extrapolation chamber was used to measure the dose rate produced by natural uranium at a variety of depths i...

Journal: :Medical physics 2007
Andrew Wroe Anatoly Rosenfeld Reinhard Schulte

Measurements were performed to assess the dose equivalent outside a primary proton treatment field, using a silicon-on-insulator (SOI) microdosimeter. The SOI microdosimeter was placed on the surface of an anthropomorphic phantom and dose equivalents were determined as a function of lateral distance from a typical passively scattered and modulated prostate treatment field. Measurements were als...

Journal: :iranian journal of radiation research 0
t. cakir department of radiation oncology, medical faculty, yuzuncu yil university 65080, van, turkey a. gur department of physicalchemistry, science and art faculty, yuzuncu yil university, 65080, van, turkey a. arasoglu department of nuclear physics, science and art faculty, yuzuncu yil university, 65080, van, turkey

background: advances in radiation dosimetry concepts and the development of primary measurement standards based on absorbed dose to water over the last decades offer the possibility to calibrate ionisation chambers directly in terms of absorbed dose to water. the aim of this study is the investigation on utility of artificial body fluid (abf) instead of water by comparing dosimetric measurement...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید