نتایج جستجو برای: deconvolution
تعداد نتایج: 7107 فیلتر نتایج به سال:
We perform an analysis of the TRACE telescope blur from EUV images. The blur pattern is discussed in terms of the telescope point spread function (PSF) for the 171 Å filter. The analysis performed consists of two steps. First an initial shape for the PSF core is determined directly from TRACE EUV images. Second, the blind deconvolution approach is used for obtaining the final PSF shape. The PSF...
We consider a deconvolution model for 3D periodic flows. We show the existence of a global attractor for the model. MCS Classification : 76D05, 35Q30, 76F65, 76D03 Key-words : Navier-Stokes equations, Large eddy simulation, Deconvolution models.
We extend deconvolution in a periodic setting to deal with functional data. The resulting functional deconvolution model can be viewed as a generalization of a multitude of inverse problems in mathematical physics where one needs to recover initial or boundary conditions on the basis of observations from a noisy solution of a partial differential equation. In the case when it is observed at a f...
Charge deconvolution infers the mass from mass over charge (m/z) measurements in electrospray ionization mass spectra. When applied over a wide input m/z or broad target mass range, charge-deconvolution algorithms can produce artifacts, such as false masses at one-half or one-third of the correct mass. Indeed, a maximum entropy term in the objective function of MaxEnt, the most commonly used ch...
We extend deconvolution in a periodic setting to deal with functional data. The resulting functional deconvolution model can be viewed as a generalization of a multitude of inverse problems in mathematical physics where one needs to recover initial or boundary conditions on the basis of observations from a noisy solution of a partial differential equation. In the case when it is observed at a f...
In this paper, we theoretically discuss about regularization on logarithm bidirectional deconvolution proposed by Claerbout et al. (2011). We hope model fitting helps reduce the unwelcome strong precursors and noise in the bidirectional deconvolution results. INTRODUCTION Bidirectional deconvolution is an ill-posed and highly non-linear problem with many unexpected traps-local minima. When we t...
In guided wave pipeline inspection, echoes reflected from closely spaced reflectors generally overlap, meaning useful information is lost. To solve the overlapping problem, sparse deconvolution methods have been developed in the past decade. However, conventional sparse deconvolution methods have limitations in handling guided wave signals, because the input signal is directly used as the proto...
Based on truncated inverse filtering, a theory for deconvolution of complex fields is studied. The validity of the theory is verified by comparing with experimental data from digital holographic microscopy (DHM) using a high-NA system (NA=0.95). Comparison with standard intensity deconvolution reveals that only complex deconvolution deals correctly with coherent cross-talk. With improved image ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید