Yoshihisa Sugimoto Yasuo Ito Masao Tomioka Tetsuya Shimokawa Yasuyuki Shiozaki Tetsuro Mazaki Masato Tanaka

Correct screw placement is especially difficult in the upper thoracic vertebrae. At the cervicothoracic junction (C7-T2), problems can arise because of the narrowness of the pedicle and the difficulty of using a lateral image intensifier there. Other upper thoracic vertebrae (T3-6) pose a problem for screw insertion also because of the narrower pedicle. We inserted 154 pedicle screws into 78 ve...

2017
Chengmin Zhang Qiang Zhou Paul M. Arnold

BACKGROUND To evaluate the safety and efficacy of lateral mass screws at C7 in the treatment of cervical degenerative disease. METHODS Patients with cervical degenerative disease who underwent posterior cervical fusion and fixation from 2009 to 2015 were included in the study. All complications were captured. Postoperative X-ray and computed tomography (CT) confirmed fusion at 6 and 12 months...

Journal: :Chinese journal of traumatology = Zhonghua chuang shang za zhi 2010
Tao Liu Wen-jie Zheng Chang-qing Li Guo-dong Liu Yue Zhou

OBJECTIVE In pedicle screw fixation, the heads of monoaxial screws need to be directed in the same straight line to accommodate the rod placement by backing out during operation, which decreases the insertional torque and internal fixation strength. While polyaxial screws facilitate the assembly of the connecting rod, but its ball-in-cup locking mechanism reduces the static compressive bending ...

2010
Joscha Bauer Turgay Efe Silke Herdrich Leo Gotzen Bilal Farouk El-Zayat Jan Schmitt Nina Timmesfeld Markus Dietmar Schofer

BACKGROUND In the present biomechanical study, the torsional stability of different interference screws, made of bovine bone, was tested. Interference screws derived from bovine bone are a possible biological alternative to conventional metallic or bioabsorbable polymer interference screws. METHODS In the first part of the study we compared the torsional stability of self-made 8 mm Interferen...

Journal: :Acta medica Okayama 2007
Kazuo Nakanishi Masato Tanaka Yoshihisa Sugimoto Toshifumi Ozaki

We performed fixation using laminar screws in 2 patients in whom lateral mass screws, pedicle screws or transarticular screws could not be inserted. One was a 56-year-old woman who had anterior atlantoaxial subluxation (AAS). When a guide wire was inserted using an imaging guide, the hole bled massively. We thought the re-insertion of a guide wire or screw would thus increase the risk of vascul...

2015
Engin Çetin Mustafa Özkaya Ümit Özgür Güler Emre Acaroğlu Teyfik Demir

Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod). In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in t...

Journal: :Spine 2008
Dirk W Kiner Christopher D Wybo William Sterba Yener N Yeni Stephen W Bartol Rahul Vaidya

STUDY DESIGN Biomechanical analysis. OBJECTIVE To determine the relative strengths of 2 different forms of revision spinal instrumentation using a validated, constant load, cyclic testing mechanism. SUMMARY OF BACKGROUND DATA Spinal fusion with instrumentation procedures are on the rise. As such, so are revision procedures. A few studies have looked at revision instrumentation techniques. B...

2010
Kousuke Iba Yasuhiro Ozasa Takuro Wada Tomoaki Kamiya Toshihiko Yamashita Mitsuhiro Aoki

BACKGROUND The locking screws target the radial styloid, theoretically provide greater stability against radial styloid fragment. However, it is unknown whether the radial styloid locking screws increased the stability of the volar plating system fixation along the entire distal radius or not. In this study, we evaluated the stability of the volar plating system fixation with or without the rad...

2014
Nancy E. Epstein

BACKGROUND More studies report the intraoperative benefits vs. risks of utilizing the O-Arm in performing pedicle screw insertion in spinal surgery. METHODS/RESULTS Several studies document the utility of CT-guided O-arm placement of pedicle/lateral mass screws. Singh et al. documented the efficacy of CT guided-O Arm placement of pedicle screws and lateral mass screws in the upper cervical sp...

Journal: :The Journal of bone and joint surgery. British volume 2006
M Richter P Droste T Goesling S Zech C Krettek

Different calcaneal plates with locked screws were compared in an experimental model of a calcaneal fracture. Four plate models were tested, three with uniaxially-locked screws (Synthes, Newdeal, Darco), and one with polyaxially-locked screws (90 degrees +/- 15 degrees ) (Rimbus). Synthetic calcanei were osteotomised to create a fracture model and then fixed with the plates and screws. Seven sp...