نتایج جستجو برای: collimator detector response
تعداد نتایج: 1033857 فیلتر نتایج به سال:
UNLABELLED We present a new rodent SPECT system (U-SPECT-II) that enables molecular imaging of murine organs down to resolutions of less than half a millimeter and high-resolution total-body imaging. METHODS The U-SPECT-II is based on a triangular stationary detector set-up, an XYZ stage that moves the animal during scanning, and interchangeable cylindric collimators (each containing 75 pinho...
We present results from the flight of two prototype CZT detectors on a scientific balloon payload in September 2000. The first detector, referred to as “CZT1,” consisted of a 10 mm × 10 mm × 2 mm CZT crystal with a single gold planar electrode readout. This detector was shielded by a combination of a passive collimator in the front, giving a 40 degree field of view and surrounded by plastic sci...
In this paper we report the development of a prototype for a new kind of detector intended for scintimammography imaging. Traditional photon counting information is available; moreover digital words representing the amplitude of each event and suitable image elaboration methods significantly enhance detector capabilities. The prototype detector is composed of a collimator and 4 imaging modules....
Abstract We present the design and testing of a prototype in-plane echelle spectrograph based on an actively controlled fiber-fed double-pass design. This system aims to be small efficient with minimum number optical surfaces—currently collimator/camera lens, cross-dispersing prism, grating reflector send light detector. It is built from catalog components has dimensions approximately 20 × 30 c...
We implemented a fully-3D ordered subsets expectation maximization (OSEM) algorithm with compensation of attenuation, distance-dependent blurring (DDB) and sensitivity modeling for SPECT performed with cone-beam collimator (CBC). The experimentally obtained detector response to point sources across FOV was fitted to a twodimensional Gauss function with its width (FWHM) varied linearly with the ...
One of the most important instruments in gamma ray spectroscopy is HPGe detector. Concept of virtual point detector was considered for Ge(Li) detector. On the basis of this concept, there is a point inside a Ge detector that can be regarded as a fictitious point detector hosting all the interactions. If there is really a point whose response can be considered similar to that of the whole real b...
In this study we investigated the characteristics of a commercial ion chamber array and its performance in the verification of radiotherapy plans. The device was the 2D Array Seven29 model (PTW, Freiburg, Germany). This is a two-dimensional detector array with 729 ionization chambers uniformly arranged in a 27 x 27 matrix with an active area of 27 x 27 cm(2). The detector short-, medium- and lo...
Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in...
A method for system matrix calculation in the case of iterative reconstruction algorithms in SPECT was implemented and tested. Due to a complex mathematical description of the geometry of the detector set-up, we developed a method for system matrix computation that is based on direct measurements of the detector response. In this approach, the influence of the acquisition equipment on the image...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید