نتایج جستجو برای: circular cone optimization

تعداد نتایج: 423658  

2003
Shu Xiao Yoram Bresler David C. Munson

We propose a new fast Feldkamp algorithm for 3-D cone beam tomography with a circular source trajectory. The algorithm is an extension of our recent fast native 2-D fan-beam reconstruction algorithm. It is based on a recursive hierarchical decomposition of the cone-beam backprojection operation into successively smaller sub-volumes. The algorithm reduces the computational complexity of the reco...

Journal: :SIAM Journal on Optimization 2006
Luis Fernando Zuluaga Juan Carlos Vera Javier Peña

An interesting recent trend in optimization is the application of semidefinite programming techniques to new classes of optimization problems. In particular, this trend has been successful in showing that under suitable circumstances, polynomial optimization problems can be approximated via a sequence of semidefinite programs. Similar ideas apply to conic optimization over the cone of copositiv...

Journal: :Journal of the Optical Society of America. A, Optics, image science, and vision 2000
A V Bronnikov

A new analytical method for tomographic image reconstruction from cone-beam projections acquired on the source orbits lying on a cylinder is presented. By application of a weighted cone-beam backprojection, the reconstruction problem is reduced to an image-restoration problem characterized by a shift-variant point-spread function that is given analytically. Assuming that the source is relativel...

Journal: :J. Applied Mathematics 2012
Zhi-Ang Zhou Jian-Wen Peng

We first introduce a new notion of the partial and generalized cone subconvexlike set-valued map and give an equivalent characterization of the partial and generalized cone subconvexlike set-valued map in linear spaces. Secondly, a generalized alternative theorem of the partial and generalized cone subconvexlike set-valued map was presented. Finally, Kuhn-Tucker conditions of set-valued optimiz...

Journal: :American Journal of Operations Research 2013

2011
Ujjal Kumar Bhowmik Reza R. Adhami

Head motion during brain CT studies can adversely affect the reconstructed image through distortion and other artifacts such as blurring and doubling, thereby losing substantial information. In this paper, we propose a method to detect and eliminate motion artifacts in Feldkamp-David-Kress (FDK) based three-dimensional (3D) cone-beam tomography. Motion detection is achieved by comparing the cor...

Journal: :British heart journal 1958
J C VAN DER SPUY

This paper is based largely on personal observations of normal and stenosed mitral valves. Some aspects that are new and some that are not in keeping with present-day concepts will be discussed. The mitral valve is a unit that consists of a so-called fibrous "ring," of two unequal cusps, of two sets of papillary muscles, and of numerous chorde tendinee. When two triangular leaflets are attached...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید