نتایج جستجو برای: brachytherapy tg 43 formalism

تعداد نتایج: 156742  

Journal: :iranian journal of radiation research 0
n. babaei bidmeshki department of energy engineering, sharif university of technology, p.o. box 1485893169, tehran, iran m. sohrabpour department of energy engineering, sharif university of technology, p.o. box 1485893169, tehran, iran s.r. mahdavi department of medical physics, faculty of medicine, tehran university of medical sciences p.o. box 1449614525, tehran, iran

background: the purpose of this project was to derive the brachytherapy dosimetric functions described by american association of physicists in medicine (aapm) tg-43 u1 based on high dose rate 192i sources. materials and methods: the method utilized included both simulation of the designed polymethyl methacrylate (pmma) phantom using the monte carlo of mcnp4c and benchmarking of the simulation ...

2016
Neda Zaker Mehdi Zehtabian Sedigheh Sina Craig Koontz Ali S. Meigooni1

Monte Carlo simulations are widely used for calculation of the dosimetric parameters of brachytherapy sources. MCNP4C2, MCNP5, MCNPX, EGS4, EGSnrc, PTRAN, and GEANT4 are among the most commonly used codes in this field. Each of these codes utilizes a cross-sectional library for the purpose of simulating different elements and materials with complex chemical compositions. The accuracies of the f...

2015
Delaram Pakravan Mahdi Ghorbani Ali Soleimani Meigooni

PURPOSE Recently a number of hypothetical sources have been proposed and evaluated for use in brachytherapy. In the present study, a hypothetical (101)Rh source with mean photon energy of 121.5 keV and half-life of 3.3 years, has been evaluated as an alternative to the existing high-dose-rate (HDR) sources. Dosimetric characteristics of this source model have been determined following the recom...

M. Sohrabpour, N. Babaei Bidmeshki, S.R. Mahdavi,

Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...

Journal: :iranian journal of medical physics 0
gholamreza raisali associate professor, radiation application research school, nuclear science and technology research institute, atomic energy organization of iran, tehran, iran mahdi sadeghi assistant professor, agricultural, medical and industrial research school, nuclear science and technology research institute, atomic energy organization of iran, karaj, iran vahideh ataeinia m. sc. in medical applications of radiation, nuclear engineering dept, faculty of engineering, science and research unit, islamic azad university, tehran, iran arjang shahvar b. sc. in physics, agricultural, medical and industrial research school, nuclear science and technology research institute, atomic energy organization of iran, karaj, iran maryam ghasemi ghonchehnazi m. sc. in medical physics, medical physics dept., faculty of medical sciences, isfahan university of medical sciences, isfahan, iran

introduction: the use of low energy isotopes such as  103 pd in brachytherapy for the treatment of cancers  such as prostate, eye, head, neck, breast and cervix is increasing. in this regard, different models of pd- 103  seeds  have  been  designed  and  manufactured  at  the  agricultural,  medical  and  industrial  research  school (amirs) of atomic energy organization of iran. in this resear...

2011
James J. Segala Gene A. Cardarelli Jessica R. Hiatt Bruce H. Curran Edward S. Sternick

In this study, we evaluate the attenuation of the dose due to barium-impregnation in the region between the surface of an electronic brachytherapy (EBT) balloon applicator for accelerated partial breast irradiation (APBI) and the prescription point at 1 cm depth in tissue. To perform the study, depth dose curves were calculated using a general purpose multi-particle transport code (FLUKA) for a...

2014
Carlos Eduardo deAlmeida Ricardo Ochoa Marilene Coelho de Lima Mariano Gazineu David Evandro Jesus Pires José Guilherme Peixoto Camila Salata Mario Antônio Bernal

High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brac...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید