نتایج جستجو برای: bending fatigue

تعداد نتایج: 97074  

Journal: :Journal of orthopaedic surgery 2015
Jerry Yongqiang Chen Zhihong Zhou Benjamin Fu Hong Ang Andy Khye Soon Yew Siaw Meng Chou Shi-Lu Chia Joyce Suang Bee Koh Tet Sen Howe

PURPOSE To compare the stiffness of locking compression plate (LCP) constructs with or without drilling the near cortex with elongated figure-of-8 holes. METHODS 24 synthetic bones were sawn to create a 10-mm gap and were fixed with a 9-hole 4.5-mm narrow LCP. In 12 bones, the near cortex of the adjacent holes to the LCP holes was drilled to create elongated figure-of-8 holes before screw ins...

2015
M. Benachour A. Belmokhtar N. Benachour

In the present investigation, an attempt has been made to use “exponential model” in the prediction of fatigue life without integrating the fatigue crack growth rate curve (FCGR). The obtained results are compared with experimental crack growth data obtained for 2024-T351 aluminum alloy for four bending V-Charpy specimens under constant amplitude loading in stress ratio range from 0.1 to 0.3 an...

Journal: :Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists 2010
Stefan Müller-Hülsbeck Philipp J Schäfer Nikolas Charalambous Hiroshi Yagi Martin Heller Thomas Jahnke

PURPOSE To examine and compare in an ex vivo study different nitinol stent designs intended for the superficial femoral artery (SFA) with regard to the appearance of fracture. METHODS Seven different 8-×40-mm nitinol stents were evaluated (Misago, Absolute, Smart, Luminexx, Sentinol, Lifestent NT, and Sinus-Superflex). Finite element analysis (FEA) was used for digitalized stent design compar...

2016
Huihui Yang Yanling Wang Xishu Wang Pan Pan Dawei Jia Filippo Berto

The effects of corrosive media on rotating bending fatigue lives (the cyclic numbers from 104 to 108) of different aluminum alloys were investigated, which involved the corrosion fatigue lives of five kinds of aluminum alloys in air, at 3.5 wt. % and 5.0 wt. % NaCl aqueous solutions. Experimental results indicate that corrosive media have different harmful influences on fatigue lives of differe...

2017
Taha Özyürek Mustafa Gündoğar Koray Yılmaz Gülşah Uslu

Background. This study compared the cyclic fatigue resistance, bending resistance and cross-sectional areas of Reciproc Blue (RPC Blue), WaveOne Gold (WOG), and Genius File (GF) NiTi rotary systems. Methods. Forty RPC Blue R25 (25/.08), 40 WOG Primary (25/.07) and 40 GF (25/.04) files were used in the present study. Flexibility of the files was determined by 45° bending test. The instruments we...

2015
Curtis D. Lee Ellis Meng

Structures and testing methods for measuring the adhesion strength, minimum bending diameter, and bending fatigue performance of thin-film polymer electronic architectures were developed and applied to Parylene–metal–Parylene systems with and without the moisture barrier Al2O3 [deposited using atomic layer deposition (ALD)]. Parylene–metal– Parylene interfaces had the strongest average peel tes...

2009
F. Pérez-Jiménez

Flexural fatigue tests are typically run under displacement or in a straincontrolled mode. In these tests, either the oscillatory displacement amplitude or strain amplitude applied to the bottom of the specimen is kept constant. The evolution of loading required to cause fatigue is then measured. Load amplitude decreases with the number of cycles, and the specimen is considered to have failed w...

Journal: :Nanotechnology 2014
Hyun-Min Seung Kyoung-Cheol Kwon Gon-Sub Lee Jea-Gun Park

Flexible conductive-bridging random-access-memory (RAM) cells were fabricated with a cross-bar memory cell stacked with a top Ag electrode, conductive polymer (poly(n-vinylcarbazole): PVK), electrolyte (polyethylene oxide: PEO), bottom Pt electrode, and flexible substrate (polyethersulfone: PES), exhibiting the bipolar switching behavior of resistive random access memory (ReRAM). The cell also ...

2011
Y. S. Pyoun C. M. Suh I. H. Cho K. Y. Lee J. H. Ahn A. Cherif B. Scholtes R. Kayumov

The spine rod in the spinal fixation system should be tough enough to support the dynamic force and flexible also for flexible movement. 5.5 mm ~ 6 mm diameter spine rods made of Ti-6Al-4V ELI are common products. Two possibilities are studied. The one is that while keeping the flexibility unchanged (using 6mm diameter), how much the fatigue strength can be increased. The other is while the fle...

2014
M. Hehenberger J. O. Nilsson

A numerical analysis of stresses generated in bending fatigue specimens has been performed employing the commercially available FEM-program ADINA. The results show that transverse bending occurs, giving rise to a stress enhancement in the edge region. A stress maximum is obtained approximately 2 mm away from the specimen edge. This result is consistent with the fact that fatigue initiation pred...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید