2008
Marcel Dobber Robert Voors Ruud Dirksen Pieternel Levelt

We have constructed a new high resolution solar reference spectrum in the spectral range between 250 and 550 nm. The primary use of this spectrum is for the calibration of the Dutch – Finnish Ozone Monitoring Instrument (OMI), but other applications are mentioned. The incentive for deriving a new high resolution solar reference spectrum is that available spectra do not meet our requirements on ...

Journal: :Circulation journal : official journal of the Japanese Circulation Society 2009
Shingo Maeda Mitsuhiro Nishizaki Noriyoshi Yamawake Takashi Ashikaga Hiroshi Shimada Mitsutoshi Asano Kensuke Ihara Tadashi Murai Hidetoshi Suzuki Hiroyuki Fujii Harumizu Sakurada Masayasu Hiraoka Mitsuaki Isobe

BACKGROUND Few studies have explored risk stratification of arrhythmic events in patients with ischemic heart diseases according to T-wave alternans (TWA) using modified moving average (MMA) method and heart rate turbulence (HRT). METHODS AND RESULTS A retrospective analysis of 63 patients who underwent MMA-based TWA and HRT divided the patients into 3 groups: group-C of 21 controls, group-O ...

Journal: :Cancer research 2003
Hirohito Yamaguchi Kapil Bhalla Hong-Gang Wang

Bax is a crucial mediator of the mitochondrial pathway for apoptosis, and loss of this proapoptotic Bcl-2 family protein contributes to drug resistance in human cancers. We report here that the endoplasmic reticulum Ca(2+)-ATPase inhibitor thapsigargin (THG) induces apoptosis of human colon cancer HCT116 cells through a Bax-dependent signaling pathway controlling the cytosolic release of mitoch...

2007
B. Veihelmann J. P. Veefkind

The Ozone Monitoring Instrument (OMI) is an imaging UV-VIS solar backscatter spectrometer and is designed and used primarily to retrieve trace gases like O3 and NO2 from the measured Earth reflectance spectrum in the UV-visible (270–500 nm). However, also aerosols are an important science target of OMI. The multi-wavelength algorithm is used to retrieve aerosol parameters from OMI spectral refl...

2008
Nickolay A. Krotkov Brittany McClure Russell R. Dickerson Simon A. Carn Can Li Pawan K. Bhartia Kai Yang Arlin J. Krueger Zhanqing Li Pieternel F. Levelt Hongbin Chen Pucai Wang Daren Lu

[1] The Dutch-Finnish Ozone Monitoring Instrument (OMI) launched on the NASA Aura satellite in July 2004 offers unprecedented spatial resolution, coupled with contiguous daily global coverage, for space-based UV measurements of sulfur dioxide (SO2). We present a first validation of the OMI SO2 data with in situ aircraft measurements in NE China in April 2005. The study demonstrates that OMI can...

2011
M. Kroon J. F. de Haan J. P. Veefkind L. Froidevaux R. Wang R. Kivi J. J. Hakkarainen

[1] In this paper we present the validation results of the operational vertical ozone profiles retrieved from the nadir observations by the Ozone Monitoring Instrument (OMI) aboard the NASA Earth Observing System (EOS) Aura platform. The operational ozone profile retrieval algorithm was developed at the Royal Netherlands Meteorological Institute and the OMI mission data has been processed and m...

Journal: :The Angle orthodontist 2008
Cheol-Hyun Moon Dong-Gun Lee Hyun-Sun Lee Jeong-Soo Im Seung-Hak Baek

OBJECTIVE To determine the success rate and the factors related to the success rate of orthodontic miniscrew implants (OMI) placed at the attached gingiva of the posterior buccal region. MATERIALS AND METHODS Four hundred eighty OMI placed in 209 orthodontic patients were examined retroactively. The sample was divided into young patients (range 10-18 years, N = 108) and adult patients (range ...

2013
G. Saponaro

The discrimination of cloudy from cloud-free pixels is required in almost any estimate of a parameter retrieved from satellite data in the ultraviolet (UV), visible (VIS) or infrared (IR) parts of the electromagnetic spectrum. In this paper we report on the development of a neural network (NN) algorithm to estimate cloud fractions using radiances measured at the top of the atmosphere with the N...

2016
Christopher Chan Miller Daniel J. Jacob Gonzalo González Abad

The Pearl River delta (PRD) is a densely populated hub of industrial activity located in southern China. OMI (Ozone Monitoring Instrument) satellite observations reveal a large hotspot of glyoxal (CHOCHO) over the PRD that is almost twice as large as any other in Asia. Formaldehyde (HCHO) and NO2 observed by OMI are also high in the PRD but no more than in other urban/industrial areas of China....

Journal: :European heart journal 2012
Hyun-Jae Kang Min-Kyung Kim Hae-Young Lee Kyung-Woo Park Whal Lee Young-Seok Cho Bon-Kwon Koo Dong-Ju Choi Young-Bae Park Hyo-Soo Kim

AIM To evaluate the long-term effects of peripheral blood stem cell therapy in myocardial infarction (MI) patients. METHODS AND RESULTS A total of 163 patients with MI who were successfully revascularized with drug-eluting stents were enrolled and randomly assigned to four groups: acute MI (AMI) cell infusion, AMI control, old MI (OMI) cell infusion, and OMI control. We compared 5 years' clin...