نتایج جستجو برای: تصویربردار ی cbct

تعداد نتایج: 106456  

2017
Shuang Wang Yiran Xu Zhengyan Shen Lijun Wang Feng Qiao Xu Zhang Minghua Li Ligeng Wu

BACKGROUND The aim of this study was to investigate the extent of the crack of a cracked tooth on an artificial simulation model with Periapical Radiography (PR) and cone beam computed tomography (CBCT) in vitro, providing the basis for early diagnosis and an appropriate treatment plan. METHODS Forty-four teeth with different extents of artificial cracks, created by exposure to liquid nitroge...

Journal: :Medical physics 2011
Sajendra Nithiananthan Sebastian Schafer Ali Uneri Daniel J Mirota J Webster Stayman Wojciech Zbijewski Kristy K Brock Michael J Daly Harley Chan Jonathan C Irish Jeffrey H Siewerdsen

PURPOSE A method of intensity-based deformable registration of CT and cone-beam CT (CBCT) images is described, in which intensity correction occurs simultaneously within the iterative registration process. The method preserves the speed and simplicity of the popular Demons algorithm while providing robustness and accuracy in the presence of large mismatch between CT and CBCT voxel values ("inte...

2015
El Hassane Bentefour Stefan Both Shikui Tang Hsiao‐Ming Lu

This study explores the potential of cone-beam computed tomography (CBCT) for monitoring relative beam range variations due to daily changes in patient anatomy for prostate treatment by anterior proton beams. CBCT was used to image an anthropomorphic pelvic phantom, in eight sessions on eight different days. In each session, the phantom was scanned twice, first at a standard position as determi...

2012
Yadollah Yaghoobzadeh Gholamreza Ghassem-Sani Seyed Abolghasem Mirroshandel Mahbaneh Eshaghzadeh Torbati

Recognizing TimeML events and identifying their attributes, are important tasks in natural language processing (NLP). Several NLP applications like question answering, information retrieval, summarization, and temporal information extraction need to have some knowledge about events of the input documents. Existing methods developed for this task are restricted to limited number of languages, an...

2016

همدقم : نیئتورپ S100B ورون طابترا لرتنک رد و دوش یم دازآ اه تیسورتسآ زا هک تسا ینیئتورپ ، لگ ی یلا دراد شـقن یسپانیس يریذپ لکش و هظفاح رد لاامتحا و . هـعلاطم ادروخرب یصاخ تیمها زا نورون و تیسورتسآ لولس ود يدرکلمع طابترا تسا ر . ياـه شوـم رد يریگداـی يور رـب پـماکوپیه نورد هـب نیئتورـپ نیا قیرزت رثا رضاح هعلاطم رد تفرگ رارق یسررب دروم ییارحص . شور اه : زا قیقحت نیا رد 40 دش هدافتسا رن ییا...

2015

Leksell Gamma Knife® IconTM with integrated Cone Beam CT (CBCT) system provides increased workflow flexibility with e.g. planning on frameless images and subsequent frameless dose delivery. The stereotactic reference is given by the CBCT images taken prior to treatment. Co-registration of the planning image volume with the CBCT volume gives the transformation mapping of the planned isocenter po...

2012
Ming X. Jia Xu Zhang Na Li Cheng B. Han

The purpose of this study was to investigate the impact of different CBCT imaging monitor units (MUs), reconstruction slice thicknesses, and planning CT slice thicknesses on the positioning accuracy of a megavoltage cone-beam computed tomography (MV-CBCT) system in image-guided radiation therapy (IGRT) in head-and-neck patients. The MV-CBCT system was a Siemens MVision, a commercial system inte...

2017
Katharina Bell Marina Heitfeld Norbert Licht Christian Rübe Yvonne Dzierma

BACKGROUND Modern radiotherapy offers various possibilities for image guided verification of patient positioning. Different clinically relevant IGRT (image guided radiotherapy) scenarios were considered with regard to their influence on dosimetric plan quality and normal tissue complication probability (NTCP). METHODS This study is based on treatment plans of 50 prostate patients. We evaluate...

2014
Imad Ali Nesreen Alsbou Ozer Algan Terence Herman Salahuddin Ahmad

The purpose of this study was to assess quantitatively elongation of mobile targets in cone-beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging. Three tissue-equivalent targets of differing sizes were inserted in an artificial thorax phantom...

Journal: :The Laryngoscope 2014
Saeed Fakhran Lea Alhilali Gayathri Sreedher Andreea C Dohatcu Stella Lee Berrylin Ferguson Barton F Branstetter

OBJECTIVES/HYPOTHESIS Cone beam computed tomography (CBCT) has emerged as a low radiation dose alternative to traditional computed tomography (CT) to evaluate the paranasal sinuses. The purpose of our study was to determine how often clinically important findings would be missed if CBCT was used routinely for sinus imaging. STUDY DESIGN Retrospective review. METHODS We evaluated all maxillo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید