نتایج جستجو برای: x ray computed
تعداد نتایج: 786524 فیلتر نتایج به سال:
BACKGROUND In computed tomography (CT), the source-detector system commonly rotates around the object in a circular trajectory. Such a trajectory does not allow to exploit a detector fully when scanning elongated objects. OBJECTIVE Increase the spatial resolution of the reconstructed image by optimal zooming during scanning. METHODS A new approach is proposed, in which the full width of the...
X-ray computed tomography (CT) systems with high resolution (also known as micro-CT systems) have been developed over the last two decades and have been used with great success in small animal studies. A micro-CT scanner is based on the same underlying physical principle as a clinical CT scanner, but it is designed for higher-resolution imaging. It produces three-dimensional (3D) tomographic da...
Most existing X-ray computed tomography (CT) techniques work in single-mounted mode and need to scan the inspected objects one by one. It is time-consuming and not acceptable for the inspection in a large scale. In this paper, we report a multi-mounted CT method and its first engineering implementation. It consists of a multi-mounted scanning geometry and the corresponding algebraic iterative r...
Introduction Conclusions References Tables Figures
Gd2O3 nanoparticles were synthesized for the first time by sol-gel combustion method and YBCO high temperature superconductor by sol-gel method. X-ray powder diffraction pattern of the nanoparticles and prepared superconductor showed single phase by both methods. The average size of Gd2O3 nanoparticles, according to the Scherrer formula, computed 29 nm, which is consistent with the results obta...
X-ray fluorescence computed tomography (XFCT) is a molecular imaging technique that can be used to sense different elements or nanoparticle (NP) agents inside deep samples tissues. However, XFCT has not been popular tool because it limited sensitivity and spatial resolution. We present benchtop system in which superfine pencil-beam source ring of spectrometers were simulated using GATE (Geant4 ...
for obtaining reservoir petrophysical properties, for example porosity, non-destructive methods such as x-ray computed tomography, ct, seems to be precise and accurate. porosity is deducted from the ct image with a single scan via different techniques, such as pore space detection by image segmentation techniques then correlation with porosity. more than one hundred samples with carbonate litho...
For obtaining reservoir petrophysical properties, for example porosity, non-destructive methods such as X-ray computed tomography, CT, seems to be precise and accurate. Porosity is deducted from the CT image with a single scan via different techniques, such as pore space detection by image segmentation techniques then correlation with porosity. More than one hundred samples with carbonate li...
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید