نتایج جستجو برای: voltage and current harmonics compensation
تعداد نتایج: 16907144 فیلتر نتایج به سال:
Abstract This paper uses Shunt Active Power Filter (SAPF) in a polluted and unbalanced mains voltage for the compensation of current harmonics along with reactive power. During reference is calculated by theory Synchronous Reference Frame (SRF). study utilizes Photovoltaic (PV) energy, renewable energy source, which maximum power point tracking (MPPT) method, an incremental conductance (InCnd),...
This paper deals with the performance of unified power quality conditioner (UPQC) based on current source converter (CSC) topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power ex...
Abstract: This paper presents a coordinated control method for a doubly-fed induction generator (DFIG)-based wind-power generation system with a series grid-side converter (SGSC) under distorted grid voltage conditions. The detailed mathematical models of the DFIG system with SGSC are developed in the multiple synchronous rotating reference frames. In order to counteract the adverse effects of ...
The power quality issues are of great concern now a days. The increasing use of power electronic devices based nonlinear loads deteriorate the quality of power. Power electronic appliances are widely used in industrial, commercial and utility system thus leading to various power quality problems. This leads to harmonics being injected into the distribution system and also reactive power burden....
In this paper a new topology for Dynamic Voltage Restorer (DVR) with high frequency link is proposed. This topology is able to compensate different types of voltage disturbances such as voltage sag, voltage swell and voltage harmonics. According to the obtained equations, this topology operates as a controllable current source to charge the series capacitor. Due to using High Frequency Transfor...
Harmonics in power distribution system are current or voltage that are integer multiples of fundamental frequency. For example if the fundamental frequency 50 Hz, then the 2-nd harmonics is 100Hz, the 3-rd is 150Hz, etc. A pure voltage or current sine wave has no distortion and no harmonics but non sinusoidal wave has distortion and harmonics. To quantify the distortion, the term total harmonic...
A Torque Control Method Based on <i>I-MR</i> Controller for IPMSM Drive With Small DC-Link Capacitor
In traditional motor drive system, large volume electrolytic capacitors are utilized to buffer energy and stabilize the dc-link voltage. However, these affect reliability of drives narrow conduction angle diode-rectifier. As a result, grid side current is distorted power factor deteriorated. order settle issues, small can replace capacitors. this paper, torque control method with voltage feed-f...
− This paper studies the possibilities of decomposition of the current in three-phase, three-wire systems based on the classic p-q theory proposed by Akagi and further developed and, respectively, on the Czarnecki’s theory. In the case of distorted current absorbed by a nonlinear load, the resulted components can be used to generate the reference compensating current in three-phase active power...
A new optimization method is proposed in this paper for finding the firing angles in multi-level voltage source inverters to eliminate low-order selective harmonics and reduce total harmonic distortion (THD) value of the output voltage. For thid end, Fourier series is used for calculating objective function and selecting specific harmonics. Regarding the nature and complexity of the employed no...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید