نتایج جستجو برای: vane test
تعداد نتایج: 813427 فیلتر نتایج به سال:
The present study concerns fluid-structure coupling phenomena occurring in a guide vane cascade of a pump-turbine scale model placed in the EPFL PF3 test rig. An advanced instrument set is used to monitor both vibrating structures and the surrounding flow. The paper highlights the interaction between vibrating guide vanes and the flow behavior. The pressure fluctuations in the stay vanes region...
Effects of Pump-turbine S-shaped Characteristics on Transient Behaviours: Experimental Investigation
A pumped storage stations model was set up and introduced in the previous paper. In the model station, the S-shaped characteristic curves was measured at the load rejection condition with the guide vanes stalling. Load rejection tests where guide-vane closed linearly were performed to validate the effect of the S-shaped characteristics on hydraulic transients. Load rejection experiments with di...
This paper presents the results of simulations of the complete three-dimensional fluid flow through the Spiral Casing, Stay Vane, Guide Vane, and then through the Francis turbine runner of the Derbendikan power station. To investigate the flow in the Francis turbine and also to identify the loads acting on the turbine blades, a three-dimensional model was prepared according to specifications pr...
Last month we began a new feature in celebration of our 20th anniversary of Hypertension. In this feature we are pleased to salute once again those special honorees and lecturers of the Council for High Blood Pressure Research (CHBPR) who later received Nobel Prize recognition for their seminal research achievement that had been recognized by the Council. Each of these individuals either had be...
Increasing the combustion temperatures in a gas turbine engine to achieve higher efficiency and power output also results in high heat loads to turbine components downstream of the combustor. The challenge of adequately cooling the nozzle guide vane directly downstream of the combustor is compounded by a complex vortical secondary flow at the junction of the endwall and the airfoil. This flow t...
The flight feathers and their coverts of a European kestrel Falco tinnunculus have been tested for their air transmissivity. The transmissivity was measured in both directions, i.e. from ventral to dorsal and vice versa; the mean difference between the two directions was less than 10 %. However, the transmissivity of the inner versus outer vanes of the remiges and coverts differed significantly...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید