نتایج جستجو برای: twisted tube heat exchanger
تعداد نتایج: 315617 فیلتر نتایج به سال:
The effect of inlet humidity conditions and inclination angle on the air side thermal hydraulic performance of a brazed aluminum heat exchanger has been investigated experimentally. The crossflow heat exchanger had flat tubes and folded fins with fin and louver pitch of 2.1 mm and 1.4 mm, respectively. The glycol temperature was held nearly isothermal at 1C, while humidity of the 12C inlet air ...
This paper describes experimental investigations on convective heat transfer in counter flow double pipe exchanger under transverse vibration for single-phase with twisted tape insert the inner tube. Experiments were conducted inserted twist ratio from 7 to 17, amplitude 23 69 mm, frequency 20 100 Hz and Reynolds number (Re) changing 10710 21420. A maximum gain of 91% Nusselt (Nu) was obtained ...
Heat exchangers are the important equipments with a variety of industrial applications including power plants, chemical, refrigeration and air conditioning industries. Helically coiled heat exchangers are used in order to obtain a large heat transfer area per unit volume and to enhance the heat transfer coefficient on the inside surface. This paper deals with the CFD simulation of helical coile...
This paper presents a numerical investigation on heat transfer enhancement by using computational fluid dynamics software. The is implemented inserting twisted tape into exchanger tube. tapes with twist ratios of 4, 6 and 8 were modified alternate axis. pitch the having rotation direction such as clockwise counterclockwise are connected 90º connection angle. Water selected working turbulent flo...
In this paper an algorithm of PID controller based on model predictive control is designed for a shell and tube heat exchanger. PID controllers and model predictive controls are two control algorithm mostly used these types of process applications. The three parameters of PID controller must be tuned to the process to obtain a satisfactory closed loop process performance. The model of the heat ...
The paper presents preliminary results of an experimental study on solar water heater with full width and 75% twisted tapes as heat transfer enhancement device. The study shows that the thermal efficiency due the use of the twisted tape increases by 4.5-8%; higher for the 75% twisted tape. Keyword Solar water heater (collector), tube-in-fin, twisted tape, thermal efficiency, performance enhance...
Effects of insertion of coiled wire in juxtaposition with twisted tapes on heat transfer rate and solar radiation without disturbing the flow inside the riser tubes in a solar flat plate collector is experimentally reconnoitered in this present work. The wire coil used as a turbulator is placed inside the riser tube while the twisted tape is inserted into the wire coil to create a continuous sw...
In this study, the effect of the tube material on the thermal stress generated in a vertical shell and tube heat exchanger is investigated. Shell and tube heat exchangers are the most common heat exchangers used in industries. One of the most common failures in these exchangers in the industry is the tube failure at the junction of the tube to tubesheet. When the shell side and the tube side fl...
This paper examines the total annual cost from economic view heat exchangers based on ant colony optimization algorithm and compared the using optimization algorithm in the design of economic optimization of shell and tube heat exchangers. A shell and tube heat exchanger optimization design approach is expanded based on the total annual cost measured that divided to area of surface and power co...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید