A true bronchial dosimeter has been designed, consisting of four 400-mesh wire screens and a filter paper. With a face velocity of 3.3 cm s(-1) for home exposure and 4.6 cm s(-1) for mine exposure, the deposition pattern on the wire screens were found to satisfactorily match the variation of the dose conversion factor (in units of mSv WL M(-1)) with the size of radon progeny from 1 to 1000 nm. ...
96 Since its development, the Early Warning dosimeter for Organic materials (EWO dosimeter) has been used as both a research and general measurement tool for the evaluation of indoor air quality for preservation of cultural heritage artefacts. The EWO dosimeter measures the integrated degradation impact of the environment, comparable to that observed on organic materials due to the synergistic ...
Pure and copper doped ZnS nanoparticles in powder form were prepared by wet chemical route method by using thioglycerol as a capping agent. The XRD studies indicate that the samples are cubic in nature. The thermoluminescence (TL) behavior of pure and copper doped ZnS has been studied for fixed 10 min UV exposure time; TL glow curve shows a single peak at 165.1°C and 184.3°C temperature respect...
Post-irradiation stability of high-dose dosimeters has traditionally been an important measurement influence quantity. Though the exceptional stability of the alanine dosimeter response with time has rendered this factor a non-issue for routine work, the archival quality of the alanine dosimeter has not been characterized. Here the alanine pellet dosimeter response is measured up to seven years...
Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...
Background: The number of interventional cardiology procedures performed has increased rapidly over the past years. While these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. The dose received by the cardiologist during interventional cardiology procedures is determi...
میزان موفقیت در پرتودرمانی به درستی و دقت میزان دز جذب شده در تومور بستگی دارد و معمولا به علت غیر عملی بودن اندازه گیری مستقیم دز جذب شده در بیماران از فانتوم استفاده می شود. در این تحقیق مقایسه دز تجویزی و دز جذبی در میدان های درمانی تنه در بیماری های هوچکین و آدنوکارسینومای رحم انجام پذیرفته است. روش درمانی را در این دو بیماری روی فانتوم اعمال کرده و دز جذبی در مرکز و نقاط مجاور تومورها با ا...
Thermoluminescence spectra of manganiferous carbonatite has been studied from 30 1C to 400 1C over the wavelength range from 200 nm to 800 nm. The natural thermoluminescence appears above 200 1C and shows continuous spectral distribution from 240 nm to 800 nm. Above 500 nm the emission appears in the form of line structure emission. These are reproduced by laboratory irradiation which also prod...