نتایج جستجو برای: tc 99m trodat 1 spect

تعداد نتایج: 2780847  

Journal: :Molecular cancer therapeutics 2007
Hyunki Kim Tandra R Chaudhuri Donald J Buchsbaum Deli Wang Kurt R Zinn

A murine, apoptosis-inducing monoclonal antibody (mTRA-8) targeting human DR5 was radiolabeled with Tc-99m. The binding affinity (K(d)) and the number of DR5 receptors were measured in MD MBA-231-derived 2LMP cell lines that were "sensitive" or "resistant" to mTRA-8 killing. Single-photon emission computed tomography and X-ray computed tomography (SPECT/CT) evaluated the Tc-99m-mTRA-8 retention...

2014
Norikazu Matsutomo Akio Nagaki Masayuki Sasaki

OBJECTIVES IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ_SPECT in...

Journal: :Journal of nuclear medicine technology 2004
Wei-Jen Shih Ramon A L Romero Mullet Timothy Primo P Milan

99mTc-Depreotide has been used on single pulmonary nodules to identify somatostatin receptor-positive lung cancer. We report that pulmonary metastases of a 78-y-old man with postradical nephrectomy for renal cell carcinoma were detected by (99m)Tc-depreotide chest SPECT. Thus, (99m)Tc-depreotide chest SPECT can be used to diagnose secondary lung cancer, such as pulmonary metastases from renal c...

Journal: :Indian Journal of Nuclear Medicine 2016

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2003
Mordechai Lorberboym Irit Minski Sorina Macadziob Galina Nikolov Pinhas Schachter

UNLABELLED The purpose of this prospective study was to evaluate the diagnostic value of early parathyroid SPECT combined with quantitative analysis as compared with planar imaging in patients undergoing minimally invasive radioguided surgery. METHODS A total of 52 consecutive patients with primary hyperparathyroidism underwent planar and SPECT parathyroid scintigraphy 2-5 d before surgery. E...

Journal: :American journal of nuclear medicine and molecular imaging 2013
Fares Alhassen Nhan Nguyen Sukhkarn Bains Robert G Gould Youngho Seo Stephen L Bacharach Xiyun Song Lingxiong Shao Grant T Gullberg Carina Mari Aparici

Cardiac single photon emission computed tomography (SPECT) cameras typically rotate too slowly around a patient to capture changes in the blood pool activity distribution and provide accurate kinetic parameters. A spatiotemporal iterative reconstruction method to overcome these limitations was investigated. Dynamic rest/stress (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) SPECT/CT was perfor...

Journal: :Annals of nuclear medicine 2003
Bulent Turgut Mustafa Unlu N Hakan Temiz Mehmet T Kitapci Mehmet L Alkan

The purpose of this study was to evaluate the feasibility and diagnostic accuracy of same day rest-stress myocardial perfusion SPECT (MP SPECT) protocol by using technetium-99m (Tc-99m) furifosmin in conjunction with dobutamine stress test in subjects in whom coronary artery disease (CAD) had been proven or excluded at coronary angiography (CA). The study group consisted of 25 patients (8 femal...

Journal: :the journal of tehran university heart center 0
shahram dabiri emam hospital, nuclear medicine department, tabriz university of medical sciences, tabriz, iran. naser aslanabadi madani heart hospital, tabriz university of medical sciences, tabriz, iran.

background: diagnosis of coronary artery disease (cad) in patients with left bundle branch block (lbbb) is considered as a challenge in cardiology due to the low accuracy of noninvasive methods such as basal and stress electrocardiography (ecg). this diagnostic challenge can be reduced but not eliminated using dipyridamole as a stress method instead of exercise. the aim of this study was to ass...

Journal: :Annals of nuclear medicine 2000
T Komori I Narabayashi R Matsui K Sueyoshi T Aratani K Utsunomiya

PURPOSE We performed technetium-99m hexakis-2-methoxyisobutylisonitrile (Tc-99m MIBI) single photon emission computed tomography (SPECT) in 23 patients with primary lung cancer between July 1993 and March 1996. We evaluated the relationships among the uptake ratio, retention index and the prognosis after radiation therapy and/or chemotherapy. MATERIALS AND METHODS Tc-99m MIBI SPECT was perfor...

Gliomas account for almost 80% of primary malignant brain tumors in adults. Magnetic Resonance imaging (MRI) is still the gold standard for diagnosis of brain tumors and brain 99mTc-tetrofosmin Single Photon Emission Computed Tomography (99mTc-tetrofosmin-SPECT) has been established as a useful tool for their evaluation. Fluorine-18–2-fluoro-2-deoxy-d-glucose positron emi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید