نتایج جستجو برای: stability hemolysis

تعداد نتایج: 312943  

Adel Baghersalimi, Afagh Hassanzadeh rad, Bahram Darbandi, Kioomars Golshekan, Simin Sajudi, Vahid Aminzadeh,

Background: Storage of platelet concentrates (PCs) at room temperature (20-24°C) limits its storage time to 5 Background: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common inherited enzyme deficiency of the human red blood cells . Most of G6PD deficient individuals are asymptomatic, but acute hemolytic anemia may be presented with nausea, vomiting, abdominal pain, headache,...

2016
Jaynish S. Shah Patsy S. Soon Deborah J. Marsh

microRNAs have emerged as powerful regulators of many biological processes, and their expression in many cancer tissues has been shown to correlate with clinical parameters such as cancer type and prognosis. Present in a variety of biological fluids, microRNAs have been described as a 'gold mine' of potential noninvasive biomarkers. Release of microRNA content of blood cells upon hemolysis dram...

2013
Michaela B. Kirschner J.James B. Edelman Steven C-H. Kao Michael P. Vallely Nico van Zandwijk Glen Reid

Cell-free microRNAs in plasma and serum have become a promising source of biomarkers for various diseases. Despite rapid progress in this field, there remains a lack of consensus regarding optimal quantification methods, reference genes, and quality control of samples. Recent studies have shown that hemolysis occurring during blood collection has substantial impact on the microRNA content in pl...

2017
David W Killilea Fabian Rohner Shibani Ghosh Gloria E Otoo Lauren Smith Jonathan H Siekmann Janet C King

Background: Plasma or serum zinc concentration (PZC or SZC) is the primary measure of zinc status, but accurate sampling requires controlling for hemolysis to prevent leakage of zinc from erythrocytes. It is not established how much hemolysis can occur without changing PZC/SZC concentrations.Objective: This study determines a guideline for the level of hemolysis that can significantly elevate P...

Journal: :Artificial organs 2014
Fiete Boehning Tzahiry Mejia Thomas Schmitz-Rode Ulrich Steinseifer

Reducing hemolysis has been one of the major goals of rotary blood pump development and in the investigational phase, the capability of hemolysis estimation for areas of elevated shear stresses is valuable. The degree of hemolysis is determined by the amplitude of shear stress and the exposure time, but to date, the exact hemolytic behavior at elevated shear stresses and potential thresholds fo...

Journal: :The American journal of emergency medicine 1989
A G Verstraete D P Vogelaers J F van den Bogaerde F A Colardyn C M Ackerman W A Buylaert

A case of fatal oral poisoning with formic acid resulting in shock, metabolic acidosis, and hemolysis is reported. The formic acid concentration on admission was 348 micrograms/mL, which, together with an increase in lactic acid, contributed to the metabolic acidosis. Because it has been suggested in the literature that formic acid might induce hemolysis via a direct cytotoxic action on the RBC...

2010
Margaret A. Lindorfer Andrew W. Pawluczkowycz Elizabeth M. Peek Kimberly Hickman Ronald P. Taylor Charles J. Parker

The clinical hallmark of paroxysmal nocturnal hemoglobinuria (PNH) is chronic intravascular hemolysis that is a consequence of unregulated activation of the alternative pathway of complement (APC). Intravascular hemolysis can be inhibited in patients by treatment with eculizumab, a monoclonal antibody that binds complement C5 thereby preventing formation of the cytolytic membrane attack complex...

Journal: :Clinica chimica acta; international journal of clinical chemistry 2014
Alberto Dolci Mauro Panteghini

The major source of errors producing unreliable laboratory test results is the pre-analytical phase with hemolysis accounting for approximately half of them and being the leading cause of unsuitable blood specimens. Hemolysis may produce interference in many laboratory tests by a variety of biological and analytical mechanisms. Consequently, laboratories need to systematically detect and reliab...

2009
Sharon A. Center

Differential Diagnosis of Hemolytic Anemia Hemolytic anemia reflects shortened RBC life span due to intravascular, extravascular, or fragmentation hemolysis. Intravascular hemolysis is primarily associated with type 1 hypersensitivity reactions, either idiopathic or secondary to another primary disease. In some cases an infectious intraerythrocytic or epierythrocytic agent or miscellaneous diso...

Journal: :Artificial organs 2006
Dhruv Arora Marek Behr Matteo Pasquali

Hemolysis in the GYRO centrifugal blood pump, under development at the Baylor College of Medicine, Houston, TX, is numerically predicted using the newly proposed tensor-based blood-damage model, as well as a traditional model. Three typical operating conditions for the pump are simulated with a special-purpose finite element-based flow solver, and a novel approach for tracing the pathlines in d...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید