نتایج جستجو برای: spectrofluorimetric analysis
تعداد نتایج: 2824446 فیلتر نتایج به سال:
A simple, sensitive and rapid spectrofluorimetric method for determination of α-tocopherol in pharmaceutical capsule and human plasma was developed and validated. The native fluorescence of α-tocopherol was measured at 334 nm with excitation at 291 nm, after extraction of α-tocopherol from human plasma hexane:dichloromethane mixture. The calibration curves were linear (R≥0.9993) in the concentr...
Spectrofluorimetric measurements on single-walled carbon nanotubes (SWNTs) isolated in aqueous surfactant suspensions have revealed distinct electronic absorption and emission transitions for more than 30 different semiconducting nanotube species. By combining these fluorimetric results with resonance Raman data, each optical transition has been mapped to a specific (n,m) nanotube structure. Op...
A spectrofluorimetric method was developed to determine residues of two β-blockers, atenolol (AT) and bisoprolol fumarate (BF), in Senegal's natural waters. The electronic absorption fluorescence spectral properties both β-blockers were investigated several organic solvent mixtures [e.g., MeOH/H2O (60/40 v/v), cyclodextrins (β-cyclodextrin, HP-β-CD], the presence surfactants (SDS, Triton X, Twe...
The fluorescence characteristics of norfloxacin (NFLX) were studied in reversed micelles which formed with sodium bis(2-ethylhexyl) sulfosuccinate (AOT)-water-octane. The influences of the environmental factors, such as the water content, AOT concentration and pH, on the fluorescence of NFLX were investigated. A novel spectrofluorimetric method for the direct determination of NFLX is proposed b...
The cationic surfactant hexadecyltrimethylammonium bromide enhances the fluorescence intensity of both molybdenum and tungsten complexes obtained with Alizarin Red S. This characteristic has been used for a sensitive simultaneous spectrofluorimetric determination of both ions over the range 32-4000 ng/ml and 49-2500 ng/ml for Mo and W, respectively. Good selectivity is achieved applying the wel...
A simple, accurate, precise, sensitive and cost-effective spectrofluorimetric method was developed validated for the estimation of Tenofovir in bulk formulation. The relative fluorescence intensity measured Distilled Water: Methanol (40:60%v/v) at an excitation wavelength 374 nm emission 409 nm. Proposed found to be linear over range 50 1000 ng/ml with correlation coefficient 0.999. using diffe...
A sensitive and inexpensive micellar-enhanced synchronous-derivative spectrofluorimetric method is described for the determination of folic acid in pharmaceutical preparations. The method is based upon derivatization of the vitamin with fluorescamine in acid solution and enhancement of the fluorescence with a surfactant. Linear fluorimetric analytical curves were obtained for folic acid concent...
Angiotensin-converting enzyme activity was measured in lumbar cerebrospinal fluid from patients with 'probable' Alzheimer's disease (n = 17) and age-matched controls (n = 19), using a spectrofluorimetric method. In contrast to a previous finding, no statistically significant difference in the mean (specific) angiotensin-converting enzyme activity was found between the two groups. No correlation...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید