نتایج جستجو برای: signal resolution
تعداد نتایج: 676645 فیلتر نتایج به سال:
stepped frequency radars attract many attentions due to their high range resolution. conventional processing technique in these radars is based on the idft. in detecting moving targets, the idft has the problems of range shifting and range spreading, which result in degrading target amplitude, loss of range accuracy and range resolution. to overcome these problems, the velocity compensation met...
The resolution of any measuring device influences significantly the achievable accuracy of the system. In this paper, the resolution limitation of measuring devices has been addressed. A theory is developed that allows a measuring device to measure beyond its resolution capability. It is theoretically proved that a very high resolution can be achieved with a very low resolution system. The appl...
High-resolution time of arrival (TOA) estimation techniques have great promise for the high range resolution required in recently developed radar systems. A widely known super-resolution TOA estimation algorithm for such applications, the multiple-signal classification (MUSIC) in the frequency domain, has been proposed, which exploits an orthogonal relationship between signal and noise eigenvec...
to date, a number of numerical methods, including the popular finite-difference time domain (fdtd) technique, have been proposed to simulate ground-penetrating radar (gpr) responses. despite having a number of advantages, the finite-difference method also has pitfalls such as being very time consuming in simulating the most common case of media with high dielectric permittivity, causing the for...
Adequate digital resolution and signal sensitivity are two critical factors for protein structure determinations by solution NMR spectroscopy. The prime objective for obtaining high digital resolution is to resolve peak overlap, especially in NOESY spectra with thousands of signals where the signal analysis needs to be performed on a large scale. Achieving maximum digital resolution is usually ...
BACKGROUND The medial temporal lobe (MTL) contains subregions that are subject to severe distortion and signal loss in functional MRI. Air/tissue and bone/tissue interfaces in the vicinity of the MTL distort the local magnetic field due to differences in magnetic susceptibility. Fast image acquisition and thin slices can reduce the amount of distortion and signal loss, but at the cost of image ...
| The objective is to explore a procedure for isolating additive noise in vowels, and estimating the signal-to-noise ratio. The method is founded on the wavelet transform, which is a family of multi-resolution analysis methods. The breakdown of sonorants into a noise and a signal constituent relates to the observation that additive noise is mostly high-frequency or low-amplitude. The segregatio...
The static characterization of the output section of the Arbitrary Waveform Generator (AWG) requires that its output signal must be digitalized by Analog to Digital Converter (ADC) with higher linearity and resolution than the device under test. In the literature, the problem of high resolution acquisition is translated to the simpler problem of low resolution and high sampling frequency acquis...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید