نتایج جستجو برای: rotary niti instrument

تعداد نتایج: 95079  

2013
Syed Mukhtar-Un-Nisar Andrabi Ashok Kumar Huma Iftekhar Sharique Alam

During root canal preparation procedures, the potential for instrument breakage is always present. When instrument breakage occurs, it leads to anxiety of the clinician and as well as a metallic obstruction of the canal which hinders further cleaning and shaping. Separated instruments must always be attempted for retrieval and if retrieval is not possible bypass should be tried. With the increa...

Journal: :journal of dentistry, tehran university of medical sciences 0
kiamars honardar assistant professor, department of endodontics, school of dentistry, shahed university, tehran, iran. hadi assadian assistant professor, department of endodontics, school of dentistry, shahed university, tehran, iran. shahriar shahab assistant professor, department of oral and maxillofacial radiology, school of dentistry, shahed university, tehran, iran. zahra jafari postgraduate student, department of endodontics, school of dentistry, shiraz university of medical sciences, shiraz, iran. ali kazemi associate professor, department of endodontics, school of dentistry, shahed university, tehran, iran. kiumars nazarimoghaddam assistant professor, department of endodontics, school of dentistry, shahed university, tehran, iran.

use of rotary nickel-titanium (niti) instruments for endodontic preparation has introduced a new era in endodontic practice, but this issue has undergone dramatic modifications in order to achieve improved shaping abilities. cone-beam computed tomography (cbct) has made it possible to accurately evaluate geometrical changes following canal preparation. this study was carried out to compare cana...

2007
Cumhur Aydin

t u C T c bstract he purpose of this study was to evaluate the topogaphy of new and used ProTaper rotary nickel-titanium NiTi) instruments by using atomic force microscope. our new and four used size S1, S2, F1, and F2 instruents were selected for this study. New and used nstruments were analyzed on 11 points along a 3-mm ection at the tip of the instrument. Quantitative meaurements according t...

2016
Károly Krajczár Enikő Varga Gyula Marada Sára Jeges Vilmos Tóth

BACKGROUND The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. MATERIAL AND METHODS Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a pha...

Journal: :Journal of endodontics 2013
Abeer M Marzouk Angie G Ghoneim

INTRODUCTION This study evaluated the effects of 2 different kinematics rotary nickel-titanium (NiTi) systems, Twisted File (TF), a continuous rotation full-sequence system, and WaveOne (WO), a reciprocating single-file system, on transportation, curvature, and volumetric changes of curved root canals by using cone-beam computed tomography. METHODS Forty mesiobuccal canals of mandibular molar...

Journal: :Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics 2006
Tibor Bartha Matthias Kalwitzki Claus Löst Roland Weiger

OBJECTIVE The objective of this study was to compare 2 preparation techniques performed under simulated clinical conditions with extended apical enlargement following determination of the optimal apical preparation size (APS). STUDY DESIGN After preflaring 240 root canals, APS was evaluated as outlined in Part I. The apical portion was shaped to APS either with rotary NiTi Lightspeed instrume...

Journal: :iranian endodontic journal 0
safi laaya department of endodontics, dental school, shiraz university of medical science, shiraz, iran leila khojastehpour department of oral radiology, dental school, shiraz university of medical sciences, shiraz, iran abdol hosein layeghnejad general practitioner, shiraz, iran

introduction: the preparation of the root canal space includes debridement, shaping and apical preparation. these procedures are challenging and constitute. the recent introduction of automated techniques for canal preparation has created considerable interest. the aim of this study was to test shaping ability of one hand instrumentation (passive step-back technique) and new rotary niti system ...

Journal: :International endodontic journal 2005
L Bjørndal C Reit

AIM To assess the adoption of new endodontic technology in a population of Danish practitioners. METHODOLOGY Members of the Copenhagen Dental Association (n = 1156) were approached with a questionnaire concerning the frequency of various endodontic procedures. Three options were available: often, occasionally and never. Responses were anonymous. The statistical analyses were performed as stud...

Journal: :International endodontic journal 2005
F Riitano

AIM To illustrate the conceptual basis and the operative procedure of the Anatomic Endodontic Technology (AET) technique and to illustrate the specific instruments used in each phase. SUMMARY The basic characteristics of the AET technique are reported. The instruments and procedure are described in three phases: coronal access, coronal-middle preparation and apical preparation. In the first p...

2011
Carlos Heilborn

_The world of endodontics has incorporated new technologies, instruments and materials in the past decade, such as operating microscopes, digital radiography, CBCT, NiTi rotary shaping files, sonic and ultrasonic instruments, and new irrigation delivery systems. However, despite all these improvements, the overall outcome, especially of non-surgical endo dontics, has not increased significantly...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید