نتایج جستجو برای: rest mpi

تعداد نتایج: 86323  

ژورنال: طب جنوب 2020
Ghaedian , Mohammad Mehdi, Ghaedian , Tahereh, Mirzaei , Mandana,

Background: Coronary Artery Disease (CAD) is one of the major causes of mortality in most countries. Electrocardiography (ECG) and myocardial perfusion imaging (MPI) are non-invasive disgnostic tests for CAD. Finding a relationship between abnormal findings in the baseline ECG and MPI findings can be helpful in better diagnosis of CAD. Materials and Methods: The present study examined ECG of pa...

Doppler-derived myocardial performance index (MPI) , defined as the s um of isovolumetric contraction and relaxation durations divided by ejection time, is an easily measured and reproducible index that shows both systolic and diastolic myocardial function. The goal of this study was to define normal values of right ventricular MPI in neonates in the first 48 to 72 hours of life. Fifty-one...

Journal: :Hellenic journal of nuclear medicine 2013
Annilina Hatutale Mariza Vorster Alfred Otoe Ankrah Paul Rheeder Mike Machaba Sathekge

The aim of this study was to assess whether there is an association between changes in the heart rate and blood pressure after dipyridamole stress and abnormal scan findings detected with gated technetium-99m methoxy isobutylisonitrile (99mTc-MIBI) myocardial perfusion imaging (MPI). A total of 200 consecutive patients with known or suspected coronary artery disease underwent MPI using a 2 days...

2017
David E. Winchester Alexander J. Bolanos Anita Wokhlu Rebecca J. Beyth Leslee J. Shaw

BACKGROUND The prevalence of ischemia on nuclear myocardial perfusion imaging (MPI) has been decreasing. Recent research has questioned the benefit of invasive revascularization for patients with moderate to severe ischemia. We hypothesized that patients with moderate to severe ischemia could routinely undergo successful revascularization. METHODS We analyzed data from 544 patients who underw...

2018
Joris D. van Dijk Jorn A. van Dalen Mohamed Mouden Jan Paul Ottervanger Siert Knollema Cornelis H. Slump Pieter L. Jager

BACKGROUND Correction of motion has become feasible on cadmium-zinc-telluride (CZT)-based SPECT cameras during myocardial perfusion imaging (MPI). Our aim was to quantify the motion and to determine the value of automatic correction using commercially available software. METHODS AND RESULTS We retrospectively included 83 consecutive patients who underwent stress-rest MPI CZT-SPECT and invasiv...

Journal: :Heart 2011
Aju P Pazhenkottil Ronny R Buechel Lars Husmann René N Nkoulou Mathias Wolfrum Jelena-Rima Ghadri Janine Kummer Bernhard A Herzog Philipp A Kaufmann

OBJECTIVE To assess the value of left ventricular (LV) dyssynchrony, using phase analysis of nuclear single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) as independent predictor of cardiac events. METHODS Phase analysis using Emory Cardiac Toolbox was applied on gated rest MPI scans to assess LV dyssynchrony in a total of 202 patients. Follow-up was obtained ...

Journal: :Prilozi 2008
Branislav Baskot S Obradovic S Rafajlovski Z Jankovic S Rusovic V Orozovic B Gligic N Ratkovic R Jung V Ivanovic M Bikicki

UNLABELLED The aim of this study was to determine and localize culprit lesion by myocardial perfusion imaging (MPI) in cases of angiographically detected coronary narrowing >or= 75% of at least one coronary artery. MATERIAL AND METHODS One hundred and thirty-two (132) patients with angiographically detected significant coronary narrowing (>or= 75% luminal stenosis of at least one major corona...

2012
Sajan Goud Lingala Edward DiBella Mathews Jacob

Background In myocardial perfusion imaging (MPI), highly accelerated acquisition can be used towards reducing the compromises in the image quality (spatio-temporal resolutions, volume coverage, SNR) routinely observed with the current clinical protocols. In this study, we demonstrate the feasibility of a recent accelerated dynamic MRI scheme, k-t SLR (based on sparse and low rank properties) (L...

2002
Frans J. Wackers Josef Machac

Myocardial perfusion imaging (MPI) utilizes an intravenously administered radiopharmaceutical to depict the distribution of nutritional blood flow in the myocardium. Perfusion imaging identifies areas of reduced myocardial blood flow associated with ischemia or scar. The relative regional distribution of perfusion can be assessed at rest, cardiovascular stress, or both. Imaging can also be perf...

Journal: :International journal of clinical and experimental medicine 2014
Mark A Ahlman Paul J Nietert Amy E Wahlquist Jill M Serguson Max W Berry Pal Suranyi Songtao Liu Kenneth M Spicer

PURPOSE In the effort to reduce radiation exposure to patients undergoing myocardial perfusion imaging (MPI) with SPECT/CT, we evaluate the feasibility of a single CT for attenuation correction (AC) of single-day rest (R)/stress (S) perfusion. METHODS Processing of 20 single isotope and 20 dual isotope MPI with perfusion defects were retrospectively repeated in three steps: (1) the standard m...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید