نتایج جستجو برای: rando phantom

تعداد نتایج: 17378  

Journal: :Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2012
Matthew T Studenski Ying Xiao Amy S Harrison

Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose whil...

Journal: :Heart 2003
E Kuon J Birkel M Schmitt J B Dahm

BACKGROUND Occupational head exposure to radiation in cardiologists may cause radiation induced cataracts and an increased risk of brain cancer. OBJECTIVE To determine the effectiveness of 0.5 mm lead equivalent caps, not previously used in invasive cardiology, in comparison with a 1.0 mm lead equivalent ceiling mounted lead glass screen. DESIGN An anthropomorphic Alderson-Rando phantom was...

2015
Emine Dilek Cakmak Nina Tuncel Bora Sindir

The aim of this study was to investigate the organ doses of patients undergoing computed tomography (CT) examination using the wide bore General Electric (GE) “Light Speed RT” unit. The head, chest and pelvic regions of the Rando-phantom were scanned with 120 kV, 200 mA, and 2.5 mm slice thickness for helical and axial modes. Thermoluminescent Dosimeter (TLD) pairs were used for the dosimetry o...

Journal: :علوم پیراپزشکی و بهداشت نظامی 0
سید سلمان ذکریایی seyed salman zakariaee department of radiology, faculty of paramedicine, aja university of medical sciences, tehran, iranگروه رادیولوژی، دانشکده ی پیراپزشکی، دانشگاه علوم پزشکی ارتش، تهران، ایران. ولی اله صبا valiallah saba department of radiology, faculty of paramedicine, aja university of medical sciences, tehran, iranگروه رادیولوژی، دانشکده ی پیراپزشکی، دانشگاه علوم پزشکی ارتش، تهران، ایران.

introduction: in diagnostic and therapeutic procedures, dosimetric studies are performed on the dosimetric systems in order to comply the radiation safety standards. monte carlo methods are used due to the high complexity and cost of patient-specific phantom construction. the high complexity of the digitized phantoms greatly increases the time and computational task of the monte carlo calculati...

Mahdi Jamali Mahdi Mommennezhad Shahrokh Naseri Tahereh yazdpour parizi

Introduction: In radiation therapy, in order to double-check the dosimetric results of the main treatment planning system (TPS), a distinct TPS, with few capacitances in terms of contouring and a variety of dose calculation algorithms is used. This system has the capability to double check the planification and the accurate prediction of dose distribution in order to be ensured...

BACKGROUND AND AIM: Due to increasing use of X-rays in diagnosis and treatment of diseases, this study aimed to measure and compares the absorbed dose in a number of sensitive organs of head and neck in different radiographic techniques.METHODS: Thermoluminescence dosimeter (TLD) and a male equivalent RANDO phantom were used to measure the absorbed dose in organs. The dosimeters were set in cer...

2015
Sarah Burleson Jamie Baker An Ting Hsia Zhigang Xu

The purpose of this paper is to demonstrate that an inexpensive 3D printer can be used to manufacture patient-specific bolus for external beam therapy, and to show we can accurately model this printed bolus in our treatment planning system for accurate treatment delivery. Percent depth-dose measurements and tissue maximum ratios were used to determine the characteristics of the printing materia...

Journal: :Physics in medicine and biology 2009
G Poludniowski P M Evans V N Hansen S Webb

A new method is proposed for scatter-correction of cone-beam CT images. A coarse reconstruction is used in initial iteration steps. Modelling of the x-ray tube spectra and detector response are included in the algorithm. Photon diffusion inside the imaging subject is calculated using the Monte Carlo method. Photon scoring at the detector is calculated using forced detection to a fixed set of no...

2013
Ho-Hsing Chen Jay Wu Keh-Shih Chuang Jia-Fu Lin Jia-Cheng Lee Jin-Ching Lin

The purpose of this study is to develop a total body irradiation technique that does not require additional devices or sophisticated processes to overcome the space limitation of a small treatment room. The technique aims to deliver a uniform dose to the entire body while keeping the lung dose within the tolerance level. The technique treats the patient lying on the floor anteriorly and posteri...

نمودار تعداد نتایج جستجو در هر سال