نتایج جستجو برای: rafsanjan fault

تعداد نتایج: 65321  

This paper investigates the fault detection of a micro parallel plate capacitor subjected to nonlinear electrostatic force. For this end Thau observer, which has good ability in fault detection of nonlinear system has been presented and governing nonlinear dynamic equation of the capacitor has been presented. Upper and lower threshold for fault detection have been obtained. The robustness of th...

ژورنال: فیزیک زمین و فضا 2015

The Kazerun Fault System (KFS) is a right-lateral strike slip fault system in the middle part of the Zagros seismogenic zone in Iran. Historical and instrumental earthquake data catalogs of this fault system show good evidence of fault interactions and seismic migrations. This study provides evidence for the migration of seismicity in the middle part of the Zagros region along the segments of t...

Journal: :international journal of civil engineering 0
m. fadaee phd student, international institute of earthquake engineering and seismology (iiees) m.k. jafari professor of geotechnical engineering research center, international institute of earthquake engineering and seismology (iiees) m. kamalian associate professor of geotechnical engineering research center, international institute of earthquake engineering and seismology (iiees) m. moosavi , assistant professor , mazandaran university a. shafiee assistant professor of geotechnical engineering research center, international institute of earthquake engineering and seismology (iiees)

during past earthquakes, many instances of building damage as a result of earthquake surface fault rupture have been observed. the results of investigating a potential mitigation scheme are presented in this paper. such plan provides a wall in the soil with the aim of surface displacement localization in the narrow pre-determined location. this may reduce the risk of the future rupture downstre...

This paper presents a method for diagnosis of eccentricity fault in a switched-reluctance motor (SRM) during offline and standstill modes. In this method, the fault signature is differential induced voltage (DIV) achieved by injecting diagnostic pulses to the motor windings. It will be demonstrated by means of results that there is a correlation between differential induced voltage and eccentri...

Active deformation in Alborz range is due to N-S convergence between Arabia and Eurasia. This paper provides geomorphic traces of regional deformation in NW Iran in order to characterize active faulting on major faults. Soltanieh and North Zanjan fault systems are involved in convergence boundary extent between South Caspian Basin and Central Iran. Soltanieh and North Zanjan faults are major re...

Journal: :journal of electric power and energy conversion systems 0

superconductor fault current limiter (sfcl) is an effective device to suppress high fault currents. this paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view.  appropriate location and type of the limiters in a hv substation is selected by a qualitative approach based on the equal area criterion. study system is simulated by...

K. Gorgani Firouzjah

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

ژورنال: حقوق پزشکی 2019

Medical treatments are divided to essential and unnecessary treatments. Treatments and cosmetic surgery in the category of unnecessary treatments and reconstructive surgery and other treatments for example heart, liver and kidney transplant surgery placed in the category of essential treatments. Compensation basis in essential treatments in Iranian law, among basics of the negligence, strict li...

By increasing the penetration level of the inverter-based distributed generations (IBDGs) in power system, their fault ride through capability has become one of the essential issues of the new grid codes. This paper proposes a novel method to limit inverter fault currents which are used in DGs. To achieve FRT, interface-inverter operates as a controlled voltage source during normal operation as...

In this paper, a new fast and accurate method for fault detection, location, and classification on multi-terminal DC (MTDC) distribution networks connected to renewable energy and energy storages presented. MTDC networks develop due to some issues such as DC resources and loads expanding, and try to the power quality increasing. It is important to recognize the fault type and location in order ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید