Journal: :Lab on a chip 2005
Henk Wensink Fernando Benito-Lopez Dorothee C Hermes Willem Verboom Han J G E Gardeniers David N Reinhoudt Albert van den Berg

A microfluidic chip with an integrated planar microcoil was developed for Nuclear Magnetic Resonance (NMR) spectroscopy on samples with volumes of less than a microliter. Real-time monitoring of imine formation from benzaldehyde and aniline in the microreactor chip by NMR was demonstrated. The reaction times in the chip can be set from 30 min down to ca. 2 s, the latter being the mixing time in...

Journal: :Applied optics 2012
Chengju Ma Liyong Ren Yiping Xu

We propose a simple and compact slow-light element by use of an optical microcoil resonator (OMR) constituted by two microfiber coils. Based on the matrix exponential method, we solve the coupled-wave equations of the OMR with n turns of microfiber coils and obtain a general solution. Simulations indicate that a tunable slow-light propagation can be obtained by controlling the coupling coeffici...

2006
Masaki Okuno Tasuku Aso Satoru Takahashi Kiyoshi Takamasu

Though there are a variety of microfabrication techniques, one that can fabricate three-dimensional metal structure by simple procedure is rarely seen. Given this fact, we suggest a new method for threedimensional microfabrication that is characterized by photocatalytic deposition. The setup for this method consists of a wavelength 405nm laser diode, a numerical aperture 0.9 objective lens, and...

2017
Julian Hafner Matthias Kuhl Michael Schwaerzle Thorsten Hehn Daniel Rossbach

The fabrication of electroplated planar copper microcoils for telemetric orthodontic applications is presented. A set of microcoils with overall dimensions of 2 × 2.5 × 0.5 mm3, track widths down to 5 μm and turn numbers up to 35 were fabricated on glass substrates. The coils were electrically characterized and assembled via flip-chip bonding onto a stress-mapping CMOS chip for smart orthodonti...

2011
V. Badilita B. Fassbender K. Kratt R. Meier D. Sakellariou J. G. Korvink U. Wallrabe

We report a single-chip probe for “magic angle coil spinning”-MACS nuclear magnetic resonance (NMR) spectroscopy. The probe consists in a wirebonded microcoil integrated with an on-chip interdigitated capacitor. This LC-circuit is resonant at 500 MHz (H Larmor frequency at 11.7 T) enabling wireless inductive coupling of the NMR signal and spinning for high resolution NMR. We demonstrate stable ...

2006
Jie WU Gary H. BERNSTEIN

“Inductively Coupled Deep Brain Stimulator” describes a chip/system design to inductively couple arbitrary waveforms to electrodes embedded in the brain for deep brain stimulation or other neurostimulation. This approach moves the conventionally implanted signal generator outside the body and provides flexibility in adjusting waveforms to investigate optimum stimulation waveforms. An “inlaid el...

Journal: :Journal of visualized experiments : JoVE 2018
Masahiro Tsuji Jacques-Olivier Coq Yuko Ogawa Yumi Yamamoto Makiko Ohshima

Intrauterine hypoperfusion/ischemia is one of the major causes of intrauterine/fetal growth restriction, preterm birth, and low birth weight. Most studies of this phenomenon have been performed in either models with severe intrauterine ischemia or models with gradient degree of intrauterine hypoperfusion. No study has been performed in a model on uniform mild intrauterine hypoperfusion (MIUH). ...

Journal: :Concepts in magnetic resonance. Part B, Magnetic resonance engineering 2010
Ravi Kc Ian D Henry Gregory H J Park Al Aghdasi Daniel Raftery

We present the construction and performance of a 20-μL active volume probe that utilizes zero-susceptibility wire for the detection transceiver coil and a 3.5 mm outer diameter thin-wall bubble flow cell to contain the sample. The probe shows good rf homogeneity, resolution, line shape and sensitivity. The sensitivity and resolution of the 20-μL probe was compared to those for several other coi...

Journal: :Magnetic resonance in medicine 2009
Franklyn A Howe Richard R A Syms Munir M Ahmad Loreta M Rodrigues John R Griffiths Ian R Young

Batch fabrication methods have been used to produce low-cost microcoils for magnetic resonance spectroscopy (MRS) that could be discarded after applications such as insertion into tissue during interventional surgery. Needle-shaped microcoils were constructed using electroplated conductors buried in shafts formed with different combinations of silicon and plastic and used to acquire in vivo (31...

1997
C. R. Neagu M. C. Elwenspoek rl

This paper discusses the modelling, design and characterization of planar microcoils to be used in telemetry systems that supply energy to miniaturized implants. Parasitic electrical effects that may become important at a.c. frequencies of several megahertz are evaluated. The fabrication process and electrical characterization of planar receiver microcoils will be described, and it will be show...