Background Fast and easily repeatable methods for commissioning procedures for brachytherapy (BT) treatment planning systems (TPS) are needed. Radiochromic film dosimetry with gamma analysis is widely used in external beam quality assurance (QA) procedures and planar film dosimetry is also increasingly used for verification of the dose distribution in BT applications. Using the gamma analysis m...
PURPOSE The purpose of this study was to evaluate the characteristics of a new rotating gamma system for stereotactic radiosurgery by comparison with a well accepted system. METHODS AND MATERIALS A novel gamma unit for stereotactic radiosurgery has been developed and distributed to 15 hospitals in China. The unit contains 30 cobalt-60 gamma radiation sources with initial activity of 200 Ci (7...
The post-exposure density growth (PEDG) is one of the characteristics of radiochromic film (RCF). In film dosimetry using RCF and a flatbed scanner, pixel values read out from the RCF are converted to dose (hereafter, film dose) by using a calibration curve. The aim of this study is to analyze the relationship between the pixel value read out from the RCF and the PEDG, and that between the film...
Since the introduction of volumetric chemical dosimetry with Fricke gel dosimeters in the 1980s, three-dimensional (3D) dosimetry has been a promising technique for the clinic, since it provides a unique methodology for 3D dose measurement of the complex conformal dose distributions achieved by modern techniques such as Intensity Modulated and Volumetric Arc Radiation Therapy. In the last decad...
This work considers a previously overlooked uncertainty present in film dosimetry which results from moderate curvature of films during the scanning process. Small film samples are particularly susceptible to film curling which may be undetected or deemed insignificant. In this study, we consider test cases with controlled induced curvature of film and with film raised horizontally above the sc...
Radiochromic film with a dye incorporated into the radiation sensitive layer [Gafchromic EBT2, Ashland, Inc.] may be digitized by a color transparency scanner, digitally processed, and calibrated so that a digital image in units of radiation absorbed dose is obtained. A transformation from raw scanner values to dose values was developed based upon a principal component analysis of the optical d...
PRESAGE is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE formulations irradiated by a 62 MeV proton beam were compared with that in water using GEANT4 Monte Carlo simulations. The dose delivered by secondary particles was also calculated. Our results s...
The Radiological Physics Center (RPC) developed two heterogeneous anthropomorphic quality assurance phantoms for use in verifying the accuracy of radiation delivery: one for intensity-modulated radiation therapy (IMRT) to the pelvis and the other for stereotactic body radiation therapy (SBRT) to the thorax. The purpose of this study was to describe the design and development of these two phanto...
BACKGROUND AND PURPOSE It is estimated that one third of the institutes applying clinical beta sources does not perform independent dosimetry. The Netherlands commission on radiation dosimetry (NCS) recently published recommended quality control procedures and detectors for the dosimetry of beta sources. The main issues of NCS Report 14 are summarized here. MATERIALS AND METHODS A dosimetry s...