نتایج جستجو برای: proximal femoral fracture

تعداد نتایج: 189639  

2016
Yoon-Suk Lee Byung-Kook Kim Ho-Jae Lee Jinmyoung Dan

In Fanconi syndrome, hypophosphatemic osteomalacia is caused by proximal renal tubule dysfunction which leads to impaired reabsorption of amino acids, glucose, urate, and phosphate. We present a rare case of a 43-year-old Korean male who was found to have insufficiency stress fracture of the femoral neck secondary to osteomalacia due to Fanconi syndrome. He had been receiving low-dose adefovir ...

Journal: :Journal of Medical Case Reports 2007
Theodoros B Grivas Olga D Savvidou Spyridon A Psarakis Pierre-Francois Bernard George Triantafyllopoulos Ioannis Kovanis Panagiotis Alexandropoulos

INTRODUCTION Fractures of the neck of the femoral component have been reported in uncemented total hip replacements, however, to our knowledge, no fractures of the neck of a cementless forged titanium alloy femoral stem coated in the proximal third with hydroxy-apatite have been reported in the medical literature. CASE PRESENTATION This case report describes a fracture of the neck of a cement...

2014
Mehmet Fatih Korkmaz Mehmet Nuri Erdem Zeliha Disli Engin Burak Selcuk Mustafa Karakaplan Abdullah Gogus

PURPOSE In this study, we aimed to report the results of a retrospective study carried out at our institute regarding cases of patients who had suffered proximal femoral fractures between January 2002 and February 2007, and who were treated with a proximal femoral nail. MATERIALS AND METHODS One hundred consecutive cases were included in the study. A case documentation form was used to obtain...

2014
Hakan Cift Engin Eceviz Necdet Sağlam Cem Coşkun Avcı Salih Söylemez Esat Uygur Korhan Ozkan

Objectives: In this study we aimed to present our treatment results of intramedullary nailing of femoral shaft fractures with compressive nailing using proximal static hole and only distal dynamic hole with one screw. Methods: Forty-three patients who had a fracture of the femoral shaft were managed between 2005 and 2008 with intramedullary nailing and the use of only one screw for distal inter...

2009
Ching-Chi Hsu Jinn Lin Yongyut Amaritsakul Takalamesar Antonius Ching-Kong Chao

Dynamic hip screw and gamma nail have been widely used to treat the patients with proximal femoral fractures, but clinical failures of those implants are still to be found. This study developed three-dimensional finite element models to investigate the biomechanical performances of the implants. Two kinds of commercially available implants (dynamic hip screw and gamma nail) and one newly design...

Journal: :The Journal of bone and joint surgery. British volume 1995
B Mahaisavariya P Songcharoen C Chotigavanich

We have compared the sonographic findings of six femoral fractures with soft-tissue interposition which required open reduction with those of a control group of 40 other femoral fractures. Ultrasound assessment before operation showed that the fractured end of the proximal fragment had penetrated the quadriceps muscle anteriorly while the distal fragment lay beneath it. Transverse scans showed ...

2013
Derek F. Amanatullah Randall Farac Thomas J. McDonald H. David Moehring Paul E. Di Cesare

Osteonecrosis of the hip accounts for about 10% of all total hip arthroplasty cases and presents a significant challenge for those patients with and without femoral head collapse. Subtrochanteric femur fractures have been reported with numerous types of proximal femoral implants. Care must be taken to avoid penetrating the lateral cortex of the proximal femur inferior to the distal border of th...

Journal: :trauma monthly 0
hanon sadoni department of orthopedic surgery, ahvaz jundishapur university of medical sciences (ajums), ahvaz, ir iran; department of orthopedic surgery, ahvaz jundishapur university of medical sciences (ajums), ahvaz, ir iran. tel: +98-9122131206; +98-6133335935 hamidreza arti department of orthopedic surgery, ahvaz jundishapur university of medical sciences (ajums), ahvaz, ir iran

conclusions surgical and post-surgical findings showed that this segment was not related to the patient’s femur. the foreign segment may have belonged to the other victim of this trauma. introduction femoral shaft fracture is one of the typical bone fractures due to high energy trauma and may occur as an open fracture. some foreign materials may enter the fracture site such as sand, cloth parti...

Journal: :anesthesiology and pain medicine 0
hamid reza amiri department of anesthesiology and intensive care, imam khomeini hospital, tehran university of medical sciences (tums), tehran, iran saeid safari department of anesthesiology, rasoul akram medical center, tehran university of medical sciences (tums), tehran, iran jalil makarem department of anesthesiology and intensive care, imam khomeini hospital, tehran university of medical sciences (tums), tehran, iran mojgan rahimi department of anesthesiology and intensive care, imam khomeini hospital, tehran university of medical sciences (tums), tehran, iran; corresponding author: mojgan rahimi, department of anesthesiology and intensive care, imam khomeini hospital, tehran university of medical sciences (tums), tehran, iran. tel: +98-2161192828, fax: +98-2166581537. e-mail: behnaz jahanshahi department of anesthesiology and intensive care, imam khomeini hospital, tehran university of medical sciences (tums), tehran, iran

background hip fracture–related pain both before and after surgery is generally reported as severe by most patients. various regional pain control modalities have been described in order to reduce pain in these patients. objectives because of the challenges of lumbar plexus block (lpb) and the fact that the effect of combined femoral nerve block/spinal anesthesia in controlling pain after ortho...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید