نتایج جستجو برای: proton range

تعداد نتایج: 727714  

Journal: :The British journal of radiology 2013
S E McGowan N G Burnet A J Lomax

The goal of radiotherapy is to achieve uniform target coverage while sparing normal tissue. In proton therapy, the same sources of geometric uncertainty are present as in conventional radiotherapy. However, an important and fundamental difference in proton therapy is that protons have a finite range, highly dependent on the electron density of the material they are traversing, resulting in a st...

2017
Maura Kirk Gary Freedman Thorsten Ostrander Lei Dong

This report aims to propose and present an evaluation of a robust pencil beam scanning proton multi-field optimized treatment planning technique for postmastectomy radiation of breast cancer patients with implanted tissue expanders containing an internal metal port. Field-specific split targets were created for optimization to prevent spots from traveling through the metal port, while providing...

2015
Takashi Ono Tatsuya Nakamura Yusuke Azami Hisashi Yamaguchi Yuichiro Hayashi Motohisa Suzuki Yoshiomi Hatayama Iwao Tsukiyama Masato Hareyama Yasuhiro Kikuchi Kenji Nemoto

BACKGROUND In an aging society, increasing number of older patients are diagnosed with esophageal cancer. The purpose of this study was to assess the clinical efficacy and safety of proton beam therapy for older patients with esophageal cancer. PATIENTS AND METHODS Older patients (age: ≥ 65 years) newly diagnosed with esophageal cancer between January 2009 and June 2013 were enrolled in this ...

2016
H. E. S. Pettersen J. Alme A. van den Brink M. Chaar D. Fehlker I. Meric O. H. Odland T. Peitzmann E. Rocco K. Ullaland H. Wang S. Yang C. Zhang D. Röhrich

Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to t...

Journal: :Physical review. B, Condensed matter 1991
Trybula Schmidt Drumheller

The mixed crystal Rb~ —„(NH4)„HzAs04 (RADA) has been investigated for several values of x(x =0, 0.12, 0.15, and 0.20) by measuring the complex dielectric permittivity along the a tetragonal axis in the temperature range from 3 to 300 K and frequency range from 1 Hz to 30 kHz. We find coexistence of ferroelectric and proton-glass order in RADA for x =0.12 and probably at x 0.15. The long-range f...

Journal: :The Review of scientific instruments 2014
M J Rosenberg A B Zylstra J A Frenje H G Rinderknecht M Gatu Johnson C J Waugh F H Séguin H Sio N Sinenian C K Li R D Petrasso V Yu Glebov M Hohenberger C Stoeckl T C Sangster C B Yeamans S LePape A J Mackinnon R M Bionta B Talison D T Casey O L Landen M J Moran R A Zacharias J D Kilkenny A Nikroo

A compact, step range filter proton spectrometer has been developed for the measurement of the absolute DD proton spectrum, from which yield and areal density (ρR) are inferred for deuterium-filled thin-shell inertial confinement fusion implosions. This spectrometer, which is based on tantalum step-range filters, is sensitive to protons in the energy range 1-9 MeV and can be used to measure pro...

2012
Vadim Moskvin Chee‐Wai Cheng Leia Fanelli Li Zhao Indra J. Das

The purpose of this study was to devise a simple semi-empirical model to estimate the range shift in clinical practices with high-Z inhomogeneity in proton beam. A semi-empirical model utilizing the logarithmic dependence on Z in stopping power from Bohr's classical approach has been developed to calculate the range shift due to the presence of inhomogeneity. Range shift from metallic plates of...

Journal: :International journal of radiation oncology, biology, physics 2010
Michael F Gensheimer Torunn I Yock Norbert J Liebsch Gregory C Sharp Harald Paganetti Neel Madan P Ellen Grant Thomas Bortfeld

PURPOSE In proton therapy, uncertainty in the location of the distal dose edge can lead to cautious treatment plans that reduce the dosimetric advantage of protons. After radiation exposure, vertebral bone marrow undergoes fatty replacement that is visible on magnetic resonance imaging (MRI). This presents an exciting opportunity to observe radiation dose distribution in vivo. We used quantitat...

Journal: :The journal of physical chemistry. A 2011
Maria Rosaria di Nunzio Boiko Cohen Abderrazzak Douhal

Steady-state and time-resolved picosecond emission studies were carried out to study the role of the proton concentration in the acid-base properties of the anticancer drug camptothecin (CPT) in its ground and electronically first excited states. The results show that, under acidic conditions, the excited-state proton-transfer (ESPT) reaction is irreversible, in contrast to previous literature ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید