نتایج جستجو برای: plane parallel chamber

تعداد نتایج: 374637  

Journal: :Differential Geometry and its Applications 2014

The evolution of texture was discussed during the formation of ultra-fine and nano grains in a magnesium alloy severely deformed through accumulative back extrusion (ABE). The microstructure and texture obtained after applying multiple deformation passes at temperatures of 100 and 250°C were characterized. The results showed that after single ABE pass at 100°C an ultrafine/nano grained microstr...

1970
R. Coombes D. Fryberger R. Piccioni D. Porat

A 20-plane wire chamber spectrometer utilizing capacitors as memory elements and suitable for operation in a magnetic field is described. The (parallel) wire planes are separated by N 1 cm. The active areas of the chambers range in size from 120 X I20 cm2 t0 200 x 240 cm2, The wire separation is 1 mm. Each readout wire is connected to a separate capacitor resulting in a 30 K-bit memory for the ...

2005
Z. L. Ji

The multi-chamber reactive silencers are widely used to reduce engine exhaust noise as well as blower intake and discharge noise. Davis et al. [1] developed a one-dimensional analytical approach, which assumes plane wave propagation in the axial direction in silencers, to predict the acoustic attenuation performance of double expansion chamber reactive silencers, and compared the predictions wi...

Journal: :European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery 2011
Hiroshi Nagamine Yushi Kawase Nobuhiro Tanaka Hiroiku Hara

Fig. 1. Three-dimensional orthogonal multi-planar reconstruction images of postmortem porcine pneumo-myocardium. In 1984, Lunkenheimer et al. reported a trans-coronary pneumo-myocardium technique to visualize myocardial architecture in Investigative Radiology. Pneumo-myocardium was produced with continuous transcoronary air injection at 600 mmHg. Capillary vessel walls were dissected and myocar...

1998
M. M. Baarmand A. Vaniachine H. Hoorani G. Mitselmakher S. Medved L. Preston

A simple network of comparators applied to the strip signals of a cathode strip chamber allows quick hit localization to within a halfstrip width, or +/a quarter-strip. A six-plane chamber with 6.4 mm wide strips was tested in a high-energy muon beam. The chamber was placed behind a 30 cm thick iron block. We show that patterns of hits localized to within a halfstrip allowed us to identify 300 ...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2007
M L Oliveira L V E Caldas

An extrapolation minichamber was developed for measuring doses from weakly penetrating types of radiation. The chamber was tested at the radiotherapeutic dose level in a beam from a (90)Sr+(90)Y check source, in a beam from a plane (90)Sr+(90)Y ophthalmic applicator, and in several reference beams from an X-ray tube. Saturation, ion collection efficiency, stabilization time, extrapolation curve...

1994
Eric Prebys Joseph Henry

A design is considered for a CsI photocathode incorporating a proportional wire anode plane. This would have the advantage over the previously considered mesh anode or near wire anode that the anode wires could be moved further away from the cathode pads, allowing position to be determined using interpolation of imaged charge. This would enable comparable or superior position resolution with la...

Journal: :Investigative ophthalmology & visual science 1984
S Nagataki D A Lee M Iri

Equations are described to derive the true anterior chamber dimensions of an eye from a photograph of its optical section. If the surface of the eye is assumed to be spherical, the three-dimensional coordinates of rays emanating from the anterior chamber to a camera can be transformed to two-dimensional coordinates on a plane, which contains rays both inside and outside of the "eye." The actual...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید