نتایج جستجو برای: pedicle screw

تعداد نتایج: 19650  

Journal: :Turkish neurosurgery 2015
Onur Yaman Teyfik Demir Arslan Kagan Arslan Mehmet Akif Iyidiker Tolga Tolunay Necip Camuscu Murat Ulutas

AIM One of the most common problems with transpedicular screws is screw pullout. This study was conducted to measure the pullout strengths of newly designed transpedicular screws. MATERIAL AND METHODS The design of the three group screws were conical cored standard pedicle screw (Type A), dual threaded pedicle screw (Type B), dual core and dual threaded pedicle screw (Type C), respectively. P...

2014
Teyfik Demir

BACKGROUND: The use of pedicle screws is becoming increasingly popular for spinal surgery practice as the technology advances. Screw pullout due to bone quality and loading conditions is one of the most common problems observed after pedicle screw fixation. Several solutions were studied to prevent screw pullout. These can be investigated under three main categories: screw design, expandable sc...

2017
Lianghai Jiang Liang Dong Mingsheng Tan Yingna Qi Feng Yang Ping Yi Xiangsheng Tang

BACKGROUND Atlantoaxial posterior pedicle screw fixation has been widely used for treatment of atlantoaxial instability (AAI). However, precise and safe insertion of atlantoaxial pedicle screws remains challenging. This study presents a modified drill guide template based on a previous template for atlantoaxial pedicle screw placement. MATERIAL AND METHODS Our study included 54 patients (34 mal...

Journal: :Journal of neurosurgery 2003
Yoshihisa Kotani Kuniyoshi Abumi Manabu Ito Akio Minami

OBJECT The authors introduce a unique computer-assisted cervical pedicle screw (CPS) insertion technique used in conjunction with specially modified original pedicle screw insertion instruments. The accuracy of screw placement as well as surgery-related outcome and complication rates were compared between two groups of patients: those in whom a computer-assisted and those in whom a conventional...

2015
Ching-Lung Tai Tsung-Ting Tsai Po-Liang Lai Yi-Lu Chen Mu-Yi Liu Lih-Huei Chen Bart O. Williams

Expansive pedicle screws significantly improve fixation strength in osteoporotic spines. However, the previous literature does not adequately address the effects of the number of lengthwise slits and the extent of screw expansion on the strength of the bone/screw interface when expansive screws are used with or without cement augmentation. Herein, four designs for expansive pedicle screws with ...

Journal: :Neurologia medico-chirurgica 2007
Gulgun Kayalioglu Mete Erturk Tuncay Varol Enis Cezayirli

Anatomical measurements of the cervical pedicle in a large series of human cervical vertebrae from 48 individuals were obtained to reduce the incidence and severity of complications caused by transpedicular screw placement. The greatest pedicle length was at C-3 and the greatest pedicle width was at C-6. Pedicle width and lateral mass thickness gradually increased from C-3 to C-6. Pedicle heigh...

2000

Introduction Transpedicular screw fixation is one of the most sophisticated procedures currently being used to stabilize the cervical spine. Anatomic studies have documented the external dimensions and angular parameters of the cervical pedicle, thereby providing the spinal surgeon with relevant information for accurate pedicle screw insertion [1,2]. Data is lacking, however, regarding its inte...

2017
Abhishek Srivastava Rajat Mahajan Ankur Nanda Geetanjali Nanda Nirajana Mishra Vijayant Kanagaraju Sahil Batra Harvinder Singh Chhabra

Study Design A retrospective computed tomography (CT)-based morphometric study of 84 C1pedicles in an Indian population focusing on critical morphometric dimensions vis-a-vis C1 pedicle screw placement. Purpose To determine the feasibility of C1 pedicle screw placement in an Indian population and propose a novel classification system for the same. Overview of Literature At present, C1 pedic...

Journal: :Arquivos de neuro-psiquiatria 2010
Bruno Perocco Braga Josaphat Vilela de Morais Marcelo Duarte Vilela

OBJECTIVE To evaluate the feasibility, safety and accuracy of pedicle screw placement in the upper thoracic spine using the free-hand technique with the aid of fluoroscopy; to analyze the methods used to verify correct screw positioning intra and postoperatively. METHOD All patients with instability of the cervicothoracic or upper thoracic spine and at least one screw placed in the segment T1...

2016
Venkatesh Krishnan Vicky Varghese Gurunathan Saravana Kumar

STUDY DESIGN Biomechanical study. PURPOSE To determine the effect of density, insertion angle and reinsertion on pull-out strength of pedicle screw in single and two screw-rod configurations. OVERVIEW OF LITERATURE Pedicle screw pull-out studies have involved single screw construct, whereas two screws and rod constructs are always used in spine fusions. Extrapolation of results using the si...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید