نتایج جستجو برای: mv filter
تعداد نتایج: 145411 فیلتر نتایج به سال:
-This paper Discuss about the problem occurring in the medium voltage distribution network such problems reactive power, harmonics and unbalanced load current compensation of Medium voltage Distribution systems. It proposes a simple and inexpensive solution to enhance power quality when a particular connection to the high voltage transmission network. It presents the design of a active power fi...
Purpose Conical collimators, or cones, are tertiary collimators that attach to a radiotherapy linac and suited for the stereotactic radiosurgery treatment of small brain lesions. The diameter most used cones makes difficult acquisition dosimetry data needed commissioning planning systems. Although many publications report dosimetric conical radiosurgery, works use different setups, which compli...
This study aimed to describe the commissioning of small field size radiosurgery cones in a 6-MV flattening filter free (FFF) beam and report our measured values. Four radiosurgery cones of diameters 5, 10, 12.5, and 15 mm supplied by Elekta Medical were commissioned in a 6-MV FFF beam from an Elekta Versa linear accelerator. The extraction of a reference signal for measuring small fields in sca...
Different types the spectrum of photons were studied; they were emitted from the flattening filter of a LINAC Varian 2100 C/D that operates at 15 MV. The simplified geometry of the LINAC head was calculated using the MCNPX code based on the studies of the materials of the flattening filter, namely, SST, W, Pb, Fe, Ta, Al, and Cu. These materials were replaced in the flattening filter to calcula...
In this paper we make an algebraic study of the variety of M V * –algebras introduced by C. C.Chang as an algebraic counterpart for a logic with positive and negative truth values. We build the algebraic theory of M V * –algebras within its own limits using a concept of ideal and of prime ideal that are very naturally related to the corresponding concepts in –groups. The main results are a subd...
The 6 MV flattening filter-free (FFF) beam has been commissioned for use with compensators at our institution. This novel combination promises advantages in mitigating tumor motion due to the reduced treatment time made possible by the greatly increased dose rate of the FFF beam. Given the different energy spectrum of the FFF beam and the beam hardening effect of the compensator, the accuracy o...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید