نتایج جستجو برای: monte carlo code fluka

تعداد نتایج: 236540  

2004
H. M. Araújo V. A. Kudryavtsev N. J. C. Spooner T. J. Sumner

We report on a comparison study of the Monte Carlo packages GEANT4 and FLUKA for simulating neutron production by muons penetrating deep underground. GEANT4 is found to generate fewer neutrons at muon energies above ∼100 GeV, by at most a factor of 2 in some materials, which we attribute mainly to lower neutron production in hadronic cascades. As a practical case study, the muon-induced neutron...

2003
G. Fehrenbacher F. Gutermuth T. Radon G. Shabratova M. Yuldasheva

Introduction Shielding calculations for the GSI future project [1] have been performed using the radiation transport code FLUKA [2, 3]. FLUKA is capable of simulating hadronic and electro-magnetic interactions of particles with matter. Here the task is to attenuate radiation generated inside experimental areas or accelerators to a dose rate not larger than 0.5μSv/h at outer walls and to estimat...

Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...

Journal: :iranian journal of radiation research 0
h. nedaie department of medical physics, tehran university of medical sciences, tehran, iran m. shariary department of nuclear engineering, shahid beheshti university, tehran, iran h. gharaati department of medical physics, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics, tehran university of medical sciences, tehran, iran m.a. mosleh-shirazi joint department of physics, royal marsden hospital and institute of cancer research, surrey, uk

abstract background: accurate methods of radiation therapy dose calculation. there are different monte carlo codesfor simulation of photons, electrons and the coupled transport of electrons and photons. mcnpis a general purpose monte carlo code that can be used for electron, photon and coupledphoton-electron transport.monte carlo simulation of radiation transport is considered to be one of the ...

ژورنال: سنجش و ایمنی پرتو 2018

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

2009
J. Vollaire A. Fassó J. C. Liu X. S. Mao A. Prinz S. H. Rokni M. Santana Leitner

The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experime...

Journal: :Radiation protection dosimetry 2015
K Biju C Sunil S P Tripathy D S Joshi T Bandyopadhyay P K Sarkar

Monte Carlo simulations have been carried out using the FLUKA code to improve the neutron ambient dose equivalent [H*(10)] response of the ZReC (zirconium-lined portable neutron counter responding satisfactorily to neutrons up to 1 GeV) by introducing various neutron absorbers in the system such as cadmium, gadolinium, natural boron, enriched (10)B and borated polythene. It was found that ZReC ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید