نتایج جستجو برای: metal on polyethylene
تعداد نتایج: 8529332 فیلتر نتایج به سال:
Photovoltaics (PV) are a promising source of clean renewable energy, but current technologies face a cost-to-efficiency trade-off that has slowed widespread implementation. We have developed a PV architecture-screening-engineered field-effect photovoltaics (SFPV)-that in principle enables fabrication of low-cost, high efficiency PV from virtually any semiconductor, including the promising but h...
The correct presentation of Table 4 is shown in this paper.
............................................................................. i Populärvetenskaplig sammanfattning ........................................ iii Preface ............................................................................... v Acknowledgements ............................................................... xi
We propose new isoreticular metal-organic framework (IRMOF) materials to increase the hydrogen storage capacity at room temperature. Based on the potential-energy surface of hydrogen molecules on IRMOF linkers and the interaction energy between hydrogen molecules, we estimate the saturation value of hydrogen sorption capacity at room temperature. We discuss design criteria and propose new IRMOF...
Patellofemoral arthroplasty is a treatment option for the relatively young patient with isolated patellofemoral osteoarthritis where conservative treatment has failed. However, despite of reasonable long term results, complications could be challenging. Loosening of the polyethylene patella component is a serious complication and has been reported in 2%. Dislocation of the polyethylene patella ...
We aimed to assess whether the immunological abnormalities which have been observed in patients with loose total hip replacements (THRs) are present in patients with a well-fixed prosthesis. We examined blood samples from 39 healthy donors, 22 patients before THR and 41 with well-fixed THRs of different types (15 metal-on-metal, 13 metal-on-polyethylene, 13 ceramic-on-ceramic). Before THR, the ...
BACKGROUND Ceramic femoral heads produce less wear of the opposing polyethylene than do metal femoral heads in wear simulation studies. This is a matched-pair analysis of the wear of ceramic and metal femoral heads on conventional polyethylene in uncemented total hip replacements in young, active patients at a minimum of fifteen years of follow-up. METHODS From June 1989 to May 1992, thirty-o...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید