نتایج جستجو برای: membrane electrode assembly

تعداد نتایج: 561410  

Journal: :journal of physical & theoretical chemistry 2012
r. aminameli m. h. fekri h. shafie m. darvishpour h. khanmohammadi

a pvc membrane fe(iii) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.the electrode exhibits a good potentiometric response for fe(iii) over a wideconcentration range 1.0×10-4 to 1.0×10-1m with a slope 19.4±0.5 mv/decade a and a working phrange of 6.5-9.0. it has a fast response time ≤30s.the best performance was observed with themembrance having the 30....

Journal: :journal of physical & theoretical chemistry 2004
h. aghaie m. giahi1 giahi m. aghaei m. arvand3

we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...

Journal: :journal of physical and theoretical chemistry 0
m. aghaie - m. h. fekri - m. giahi - e. baghdar - s. farhadi -

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :Sustainability 2022

The contact pressure between bipolar plates (BPPs) and a membrane electrode assembly (MEA) has key impact on Proton Exchange Membrane Fuel Cell (PEMFC) performance. However, it is difficult to obtain the combined with operating temperature action via finite element analysis (FEA) model, resulting in limited calculation resources for problem of multiscale thermo-mechanical coupled full-dimension...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2010
mohammad mazloum-ardakani roya mazidi mohammad hossein mashhadizadeh hossein naeimi kobra rabiei

in this work we introduce a practical use of synthesized schiff base metal complex in sensing application. a new perchlorate-selective electrode based on the complex n, n'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (ii) [cul] as the membrane carrier was developed. the electrode exhibits a good  nernstian slope of -55.0 ± 1.0 mv/decade and a linear range of  for perchlorate. the limit o...

2009
Sandeep Unnikrishnan Jitender Kumar Marcus Louwerse

Of course not! Humankind has cleared a lot of survival tests before reaching this point in time and shall smartly find out new ways to evolve through these hard times too. As a solution to the world energy and environmental crisis, scientists with foresight have been developing hydrogen based clean power generators: The Fuel Cells. Fuel cells are electrochemical devices which convert chemical e...

In order to present a new and high performance structure of PEM fuel cell and study the influence of the flow direction and distribution on the rate of reactants diffusion, three novel models of vertical reactant flow injection into the anode and cathode reaction area field have been introduced. They consist of one inlet and two inlets and also a continuous channel. The governing equations on t...

2009
Sharonmoyee Goswami Jay Benziger Nan Yao

The recent wave of interest in sustainability has brought the benefits of fuel cells into the public sphere. Polymer electrolyte membrane fuel cells provide clean and renewable energy, but are subject to degradation. Given the possibilities for use in remote applications, it is necessary to understand and minimize degradation of fuel cell components. Here we analyze common types of degradation ...

Journal: :journal of physical & theoretical chemistry 2009
m. zawari m. giahi h. aghaie

in this research, a pvc membrane electrode for manganese (ii) ions based on n-(2-picolinamidoethyl)picolinamide as neutral carrier was prepared. the electrode exhibits a nemstian responseover mn(ii) concentration range of (1.0 x10-5 t01.0 x 10-1m) with a slope of 29.3±0.5 mv perdecade of concentration with a working ph range of 4.0-9.0. it has a fast response time (

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید