نتایج جستجو برای: mcnp4c code

تعداد نتایج: 167954  

ژورنال: سنجش و ایمنی پرتو 2015

In regard with increasing use of brachytherapy for treatment of cancer, especially prostate cancer, dosimetry of the organs surrounding prostate is necessary. The received dose by prostate is relatively high and the healthy organs surrounding prostate are potentially at a risk of high dose too. In this paper, the doses delivered to the prostate and organs of interest were calculated by MCNP4C c...

Introduction: 103Pd is a low energy source, which is used in brachytherapy. According to the standards of American Association of Physicists in Medicine, dosimetric parameters determination of brachytherapy sources before the clinical application was considered significantly important. Therfore, the present study aimed to compare the dosimetric parameters of the target source using the water ph...

Introduction: One of the important problems of using high energy linacs is the production of photoneutrons. High energy medical linacs produce secondary neutrons. These phtoneutrons increase patient dose   Materials and Methods: In this study, the effect of plastic trays on spectrum of photoneutrons produced by 18MV linac is investigated using the MCNP4C code...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه فردوسی مشهد - دانشکده علوم پایه 1392

غده تیروئید می تواند دستخوش بیماری های متفاوتی شود که از جمله آنها پرکاری آن می باشد. یکی از روش های درمان پرکاری تیروئید استفاده از ید 131 می باشد. هدف اصلی در درمان با رادیوایزوتوپ ید ???، ایجاد بیشترین دوز جذبی در غده تیروئید و کمترین دوز ممکن در سایر اندام هاست؛ تا بیشترین اثر درمانی و کمترین عوارض جانبی ایجاد شود. برای سنجش توزیع دوز در بافت تیروئید معمولا توزیع یکنواخت ید در حجم تیروئید د...

ژورنال: :مجله دانشگاه علوم پزشکی شهید صدوقی یزد 0
ام لیلا احمدی ol ahmadi faculty of physics, shahrood university of tecnology, shahroodفیزیک هسته ای، دانشکده فیزیک، دانشگاه صنعتی شاهرود حسین توکلی عنبران h tavakoli-anbaran faculty of physics, shahrood university of tecnology, shahroodگروه فیزیک، دانشکده فیزیک، دانشگاه صنعتی شاهرود

مقدمه: چشمه 103pd منبع کم انرژی می باشد که در براکی تراپی مورد استفاده قرار می گیرد. طبق توصیه های انجمن فیزیک پزشکی آمریکا تعیین پارامترهای دزیمتری چشمه های براکی تراپی قبل از کاربرد کلینیکی، از اهمیت ویژه ای برخوردار است. در این تحقیق پارامترهای دزیمتری چشمه مورد نظر با استفاده از فانتوم آب و بافت نرم محاسبه شده و نتایج با یکدیگر مقایسه شده اند. روش بررسی: پارامترهای دزیمتری طبق پروتکل tg-43u...

2017
A. A. Mowlavi

Theoretical and experimental dosimetric studies have been supplied useful information on the dependence of the brachytherapy source geometry and materials (1-5). Usually, Monte Carlo method is used to define dose distribution function, the radial dose variation, and the dose calculation close to the source in brachytherapy. Chen et al. (6). calculated the distribution of absorbed dose around co...

2013
Sedigheh Sina Reza Faghihi Ali Soleimani Meigooni Zahra Siavashpour Mohammad Amin Mosleh-Shirazi

BACKGROUND The old Treatment Planning Systems (TPSs) used for intracavitary brachytherapy with Cs-137 Selectron source utilize traditional dose calculation methods, considering each source as a point source. Using such methods introduces significant errors in dose estimation. As of 1995, TG-43 is used as the main dose calculation formalism in treatment TPSs. OBJECTIVES The purpose of this stu...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه اراک - دانشکده علوم انسانی 1389

از مهمترین ابزار برای مونیتورینگ افراد پرتوکار در محیط های رادیواکتیو دزیمتر فردی می باشد. موضوع این پژوهش تحقیق بر روی دزیمتر نوترون گامایی است که از بج، کارت tld مدل6 7 7 6 و فیلتر کادمیوم تشکیل شده است. هدف این پژوهش تعیین بهترین مکان برای قرار گرفتن فیلتر کادمیوم و اصلاح الگوریتم محاسبه دز است، به نحوی که خطای حاصل از نوترون های حرارتی به حداقل ممکن برسد. میزان نرخ دز آزمایشگاه کالیبراسیو...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه کاشان 1389

در این پایان نامه آهنگ دز هم ارز و شار نوترون ها ی حاصل از چشمه کالیفرنیم-252، برای ضخامت های مختلف از نه ماده آب، پارافین، پلی اتیلن، بتن، آهن، گرافیت، پلی بور، بوروپلی اتیلن وکربید بورون درگستره انرژی10-8 evتا 16 mev با استفاده ازکد محاسباتی mcnp4c که مبتنی بر روش مونت کارلو می باشد، محاسبه و ارائه شده است. از آنجایی که کد mcnp4c تمام برهم کنش های نوترون با ماده را با تمام جزئیات آن ها در نظر...

2002
Hamid Tagziria Neil Roberts Andrew Bennett David J Thomas Martyn Sené

An extensive programme was successfully carried out during the 1995 to 1998 NMS programme to recalibrate and model by Monte Carlo simulations the characteristics of two NPL long counters that are routinely used to standardise neutron fluences [Ta98,Ta00] for neutron energies above 500 keV. The present work is a continuation of it in that the counters responses and effective centres have been me...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید