نتایج جستجو برای: knee prosthesis

تعداد نتایج: 93113  

Journal: :Journal of biomechanics 2004
Tomaso Villa Francesco Migliavacca Dario Gastaldi Maurizio Colombo Riccardo Pietrabissa

The evaluation of contact areas and pressures in total knee prosthesis is a key issue to prevent early failure. The first part of this study is based on the hypothesis that the patterns of contact stresses on the tibial insert of a knee prosthesis at different stages of the gait cycle could be an indicator of the wear performances of a knee prosthesis. Contact stresses were calculated for a mob...

Journal: :Orthopedics 2013
Alessandro Bistolfi Sebastien Lustig Federica Rosso Paola Dalmasso Maurizio Crova Giuseppe Massazza

Rotating hinge knee prostheses have been developed as an advancement of the fixed hinge models. Some authors suggest that this type of prosthesis is associated with a greater risk of aseptic loosening because of the increased stresses to the bone-prosthesis interface; therefore, they are scarcely used as primary implants. The current authors evaluated of a series of 98 rotating hinge knee arthr...

Journal: :Prosthetics and orthotics international 1992
E Isakov J Mizrahi Z Susak I Onna

Stump length is an important factor in attaining successful prosthetic rehabilitation in below-knee (BK) amputees. Stability of the stump-prosthesis complex is impaired in the case of a stump shorter than 10 cm. Thus, fitting a prosthesis to a BK amputee with a stump which is very short often requires the use of different prosthetic techniques. In this work, the authors suggest the use of a Swe...

Journal: :Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 2015
Zhen Wei Lui Mohammed I Awad Alireza Abouhossein Abbas A Dehghani-Sanij Neil Messenger

This article presents a virtual prototyping study of a semi-active lower limb prosthesis to improve the functionality of an amputee during prosthesis-environment interaction for level ground walking. Articulated ankle-foot prosthesis and a single-axis semi-active prosthetic knee with active and passive operating modes were considered. Data for level ground walking were collected using a photogr...

2011
Kebin Yuan Jinying Zhu Qining Wang Long Wang

Current finite-state control strategies for powered below-knee prosthesis, though effective to the normal gait, can not eliminate the disturbance of abnormal gaits such as slip and stamp. In addition, toe joint is not taken into consideration. This paper presents a finite-state control strategy for a powered below-knee prosthesis with ankle and toe. We first introduce the concerned prosthesis p...

2017
Philip Johannes Felix Leute Ahmed Hammad Frank Braatz Hans - Michael Klinger

Objective: Few studies have described the complications leading to transfemoral amputation after total knee arthroplasty. The aim of this study was to demonstrate which long term prosthesis-related complications can lead to the loss of a limb after knee joint replacement and to provide clinical guidance regarding the situations that generate an increased likelihood of a patient requiring above ...

Journal: :Journal of Bionic Engineering 2021

Abstract As the essential technology of human-robotics interactive wearable devices, robotic knee prosthesis can provide above-knee amputations with functional compensations to realize their physical and psychological social regression. With development mechanical mechatronic science technology, fully active that subjects actuating torques has demonstrated a better wearing performance in slope ...

Journal: :Prosthetics and orthotics international 1985
E J Boldingh T Van Pijkeren D W Wijkmans

A study is reported on the value of a modified KBM prosthesis compared with other types of prostheses. Recently a new type of below-knee prosthesis (the so called modified KBM prosthesis) was introduced in the Netherlands. This prosthesis is now frequently used as a substitute for more conventional types. A study was carried out on the value of this new prosthesis, compared with the more conven...

Journal: :The Journal of bone and joint surgery. British volume 2010
Y-H Kim Y Choi J-S Kim

We undertook a study in which 138 female patients with a mean age of 71.2 years (51 to 82) received a standard NexGen CR-flex prosthesis in one knee and a gender-specific NexGen CR-flex prosthesis in the other. The mean follow-up period was 3.25 years (3.1 to 3.5). The aspect ratios of the standard and gender-specific prostheses were compared with that of the distal femur. The mean post-operati...

Journal: :Prosthetics and orthotics international 1984
O Friberg

The length of the lower limb prosthesis was compared with the length of the contralateral lower extremity in 113 Finnish war-disabled amputees by a radiological weight bearing method developed by the author. Considering a shortening of 10 mm for above-knee prostheses and of 5 mm for below-knee prostheses as tolerance limits, the length of the prosthesis was acceptable only in 17 cases (15% of t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید